Volltext-Downloads (blau) und Frontdoor-Views (grau)
  • search hit 1 of 1
Back to Result List

Position observation for proportional solenoid valves by signal injection

  • The method of signal injection is investigated for position estimation of proportional solenoid valves. A simple observer is proposed to estimate a position-dependent parameter, i.e. the eddy current resistance, from which the position is calculated analytically. Therefore, the relationship of position and impedance in the case of sinusoidal excitation is accurately described by consideration of classical electrodynamics. The observer approach is compared with a standard identification method, and evaluated by practical experiments on an off-the-shelf proportional solenoid valve.

Export metadata

Additional Services

Search Google Scholar

Statistics

frontdoor_oas
Metadaten
Author:Tristan BraunORCiD, Johannes ReuterORCiD, Joachim RudolphORCiD
DOI:https://doi.org/10.1016/j.ifacol.2016.10.513
ISSN:2405-8963
Parent Title (English):7th IFAC Symposium on Mechatronic Systems, MECHATRONICS 2016, Loughborough University, Leicestershire, UK, 5—8 September 2016 (IFAC-PapersOnLine Vol. 49, Iss. 21)
Document Type:Conference Proceeding
Language:English
Year of Publication:2016
Release Date:2019/05/16
Tag:Hydraulic actuators; Electromagnetic devices; Magnetic fields; Observers; Parameter estimation
First Page:74
Last Page:79
Note:
Volltextzugriff für Angehörige der Hochschule Konstanz möglich.
Relevance:Keine peer reviewed Publikation (Wissenschaftlicher Artikel und Aufsatz, Proceeding, Artikel in Tagungsband)
Open Access?:Nein
Licence (German):License LogoUrheberrechtlich geschützt