Refine
Document Type
- Conference Proceeding (50) (remove)
Keywords
- Accelerometers (1)
- Activity monitoring (1)
- Ambient assisted living (1)
- Apnoe (1)
- Assisted living (1)
- Atmung (1)
- Atmungssignal (1)
- Automotive (1)
- BCG (2)
- Ballistocardiography (1)
- Ballistokardiographie (1)
- Bewegung (1)
- Bewegungssignal (1)
- Bio-vital data (1)
- Biomedical Signal Capturing (1)
- Biosignal analysis (1)
- Biosignal processing (1)
- Biovital signal (2)
- Breathing (1)
- Breathing rate (1)
- Common Criteria (1)
- Convolution (1)
- Convolutional neural network (1)
- Correlation (1)
- Cross Site Scripting (1)
- Data fusion (1)
- Deep Convolutional Neural Network (1)
- Deep learning (1)
- Driving (1)
- Drowsiness (1)
- ECG (5)
- EKG (1)
- EMG (1)
- Electrocardiography (2)
- Electromyography (1)
- FSR sensor (1)
- Force resistor sensor (1)
- GDPR (1)
- Heart rate (4)
- Herzfrequenz (2)
- Illuminance (1)
- Impedance measurement (1)
- Internet of Things (1)
- Kontaktloses Hardware-System (1)
- Low-pass filters (1)
- Machine learning (1)
- Maschinelles Lernen (1)
- Monitoring (1)
- Movement detection (2)
- Multinomial logistic regression (1)
- Neuronal Netze (1)
- Non-invasive (1)
- Non-invasive sleep study (1)
- PHP (1)
- PPG (1)
- PSG (1)
- PSQI (1)
- Photoplethysmography (1)
- Physical activity (1)
- Pressure sensor (1)
- Pressure sensors (2)
- Privacy by Design (1)
- Requirements Engineering (1)
- Residual Neural Network (1)
- Respiration Rate (1)
- Respiration rate (1)
- Respiratory sounds (1)
- SQL Injection (1)
- Schlaf (1)
- Schlafanalyse (1)
- Schlafphasen (1)
- Schlafphasenerkennung (1)
- Schlafstadien (1)
- Schlafstudie (1)
- Security by Design (1)
- Sensor Bed (1)
- Sensor grid (1)
- Sensors (1)
- Signal processing (2)
- Skin (1)
- Sleep (2)
- Sleep Stages (1)
- Sleep apnea (1)
- Sleep apnoea (1)
- Sleep efficiency (1)
- Sleep latency (1)
- Sleep medicine (3)
- Sleep phase (1)
- Sleep positions (1)
- Sleep quality (3)
- Sleep stages (2)
- Sleep study (8)
- Sleep tracking (1)
- Sleep/Wake states (1)
- Smart Home (1)
- Smart bed (1)
- Smart cushion (1)
- Smart home (1)
- Smart-care (1)
- Static Code Analysis (1)
- Stethoscope (1)
- Stress (3)
- Stress detection (2)
- Stress measurement (1)
- System design (1)
- Test Suite (1)
- Wearable (1)
- Zeitreihenklassifikation (1)
Institute
- Fakultät Informatik (50) (remove)
Dynamic Real-Time Range Queries (DRRQ) are a common means to handle mobile clients in high-density areas where both, clients requested by the query and the inquirers, are mobile. In contrast to the very well-known continuous range queries, only a few approaches, such as Adaptive Quad Streaming (AQS), address the mandatory scalability and real-time requirements of these so-called ad-hoc mobility challenges. In this paper we present the highly decentralized solution Adaptive Quad Streaming Flexible (AQSflex) as an extension of the already existing more theoretical AQS approach. Beside a highly distributed cell structure without data structures and a lightweight streaming communication, we use a multi-cell-assignment on limited pool resources instead of an idealistic unlimited cell-per-server assignment. The described experimental results show the potential of our local capacity balancing scheme for cell handover in a strongly decentralized setting. Leafs of a cell hierarchy define a kind of self-optimizing fuzzy edge for the processing resources in high-density systems without any centralized controlling or cloud component.
Systematic Generation of XSS and SQLi Vulnerabilities in PHP as Test Cases for Static Code Analysis
(2022)
Synthetic static code analysis test suites are important to test the basic functionality of tools. We present a framework that uses different source code patterns to generate Cross Site Scripting and SQL injection test cases. A decision tree is used to determine if the test cases are vulnerable. The test cases are split into two test suites. The first test suite contains 258,432 test cases that have influence on the decision trees. The second test suite contains 20 vulnerable test cases with different data flow patterns. The test cases are scanned with two commercial static code analysis tools to show that they can be used to benchmark and identify problems of static code analysis tools. Expert interviews confirm that the decision tree is a solid way to determine the vulnerable test cases and that the test suites are relevant.
Identifikation von Schlaf- und Wachzuständen durch die Auswertung von Atem- und Bewegungssignalen
(2021)
Preliminary results of homomorphic deconvolution application to surface EMG signals during walking
(2021)
Homomorphic deconvolution is applied to sEMG signals recorded during walking. Gastrocnemius lateralis and tibialis anterior signals were acquired according to SENIAM recommendation. MUAP parameters like amplitude and scale were estimated, whilst the MUAP shape parameter was fixed. This features a useful time-frequency representation of sEMG signal. Estimation of scale MUAP parameter was verified extracting the mean frequency of filtered EMG signal, extracted from the scale parameter estimated with two different MUAP shape values.
Normal breathing during sleep is essential for people’s health and well-being. Therefore, it is crucial to diagnose apnoea events at an early stage and apply appropriate therapy. Detection of sleep apnoea is a central goal of the system design described in this article. To develop a correctly functioning system, it is first necessary to define the requirements outlined in this manuscript clearly. Furthermore, the selection of appropriate technology for the measurement of respiration is of great importance. Therefore, after performing initial literature research, we have analysed in detail three different methods and made a selection of a proper one according to determined requirements. After considering all the advantages and disadvantages of the three approaches, we decided to use the impedance measurement-based one. As a next step, an initial conceptual design of the algorithm for detecting apnoea events was created. As a result, we developed an activity diagram on which the main system components and data flows are visually represented.
Respiratory diseases are leading causes of death and disability in the world. The recent COVID-19 pandemic is also affecting the respiratory system. Detecting and diagnosing respiratory diseases requires both medical professionals and the clinical environment. Most of the techniques used up to date were also invasive or expensive.
Some research groups are developing hardware devices and techniques to make possible a non-invasive or even remote respiratory sound acquisition. These sounds are then processed and analysed for clinical, scientific, or educational purposes.
We present the literature review of non-invasive sound acquisition devices and techniques.
The results are about a huge number of digital tools, like microphones, wearables, or Internet of Thing devices, that can be used in this scope.
Some interesting applications have been found. Some devices make easier the sound acquisition in a clinic environment, but others make possible daily monitoring outside that ambient. We aim to use some of these devices and include the non-invasive recorded respiratory sounds in a Digital Twin system for personalized health.
A residual neural network was adapted and applied to the Physionet/Computing data in Cardiology Challenge 2020 to detect 24 different classes of cardiac abnormalities from 12-lead. Additive Gaussian noise, signal shifting, and the classification of signal sections of different lengths were applied to prevent the network from overfitting and facilitating generalization. Due to the use of a global pooling layer after the feature extractor, the network is independent of the signal’s length. On the hidden test set of the challenge, the model achieved a validation score of 0.656 and a full test score of 0.27, placing us 15th out of 41 officially ranked teams (Team name: UC_Lab_Kn). These results show the potential of deep neural networks for ap- plication to raw data and a complex multi-class multi-label classification problem, even if the training data is from di- verse datasets and of differing lengths.
Ballistocardiography (BCG) can be used to monitor heart rate activity. Besides, the accelerometer should have high sensitivity and minimal internal noise; a low-cost approach was taken into consideration. Several measurements have been executed to determine the optimal positioning of a sensor under the mattress to obtain a signal strong enough for further analysis. A prototype for an unobtrusive accelerometer-based measurement system has been developed and tested in a conventional bed without any specific extras. The influence of the human sleep position for the output accelerometer data was tested. The obtained results indicate the potential to capture BCG signals using accelerometers. The measurement system can detect heart rate in an unobtrusive form in the home environment.
The main aim of presented in this manuscript research is to compare the results of objective and subjective measurement of sleep quality for older adults (65+) in the home environment. A total amount of 73 nights was evaluated in this study. Placing under the mattress device was used to obtain objective measurement data, and a common question on perceived sleep quality was asked to collect the subjective sleep quality level. The achieved results confirm the correlation between objective and subjective measurement of sleep quality with the average standard deviation equal to 2 of 10 possible quality points.