The influence of sleep on human life, including physiological, psychological, and mental aspects, is remarkable. Therefore, it is essential to apply appropriate therapy in the case of sleep disorders. For this, however, the irregularities must first be recognised, preferably conveniently for the person concerned. This dissertation, structured as a composition of research articles, presents the development of mathematically based algorithmic principles for a sleep analysis system. The particular focus is on the classification of sleep stages with a minimal set of physiological parameters. In addition, the aspects of using the sleep analysis system as part of the more complex healthcare systems are explored. Design of hardware for non-obtrusive measurement of relevant physiological parameters and the use of such systems to detect other sleep disorders, such as sleep apnoea, are also referred to. Multinomial logistic regression was selected as the basis for development resulting from the investigations carried out. By following a methodical procedure, the number of physiological parameters necessary for the classification of sleep stages was successively reduced to two: Respiratory and Movement signals. These signals might be measured in a contactless way. A prototype implementation of the developed algorithms was performed to validate the proposed method, and the evaluation of 19324 sleep epochs was carried out. The results, with the achieved accuracy of 73% in the classification of Wake/NREM/REM stages and Cohen's kappa of 0.44, outperform the state of the art and demonstrate the appropriateness of the selected approach. In the future, this method could enable convenient, cost-effective, and accurate sleep analysis, leading to the detection of sleep disorders at an early stage so that therapy can be initiated as soon as possible, thus improving the general population's health status and quality of life.
Identifikation von Schlaf- und Wachzuständen durch die Auswertung von Atem- und Bewegungssignalen
(2021)
Preliminary results of homomorphic deconvolution application to surface EMG signals during walking
(2021)
Homomorphic deconvolution is applied to sEMG signals recorded during walking. Gastrocnemius lateralis and tibialis anterior signals were acquired according to SENIAM recommendation. MUAP parameters like amplitude and scale were estimated, whilst the MUAP shape parameter was fixed. This features a useful time-frequency representation of sEMG signal. Estimation of scale MUAP parameter was verified extracting the mean frequency of filtered EMG signal, extracted from the scale parameter estimated with two different MUAP shape values.
Normal breathing during sleep is essential for people’s health and well-being. Therefore, it is crucial to diagnose apnoea events at an early stage and apply appropriate therapy. Detection of sleep apnoea is a central goal of the system design described in this article. To develop a correctly functioning system, it is first necessary to define the requirements outlined in this manuscript clearly. Furthermore, the selection of appropriate technology for the measurement of respiration is of great importance. Therefore, after performing initial literature research, we have analysed in detail three different methods and made a selection of a proper one according to determined requirements. After considering all the advantages and disadvantages of the three approaches, we decided to use the impedance measurement-based one. As a next step, an initial conceptual design of the algorithm for detecting apnoea events was created. As a result, we developed an activity diagram on which the main system components and data flows are visually represented.
A residual neural network was adapted and applied to the Physionet/Computing data in Cardiology Challenge 2020 to detect 24 different classes of cardiac abnormalities from 12-lead. Additive Gaussian noise, signal shifting, and the classification of signal sections of different lengths were applied to prevent the network from overfitting and facilitating generalization. Due to the use of a global pooling layer after the feature extractor, the network is independent of the signal’s length. On the hidden test set of the challenge, the model achieved a validation score of 0.656 and a full test score of 0.27, placing us 15th out of 41 officially ranked teams (Team name: UC_Lab_Kn). These results show the potential of deep neural networks for ap- plication to raw data and a complex multi-class multi-label classification problem, even if the training data is from di- verse datasets and of differing lengths.
Ballistocardiography (BCG) can be used to monitor heart rate activity. Besides, the accelerometer should have high sensitivity and minimal internal noise; a low-cost approach was taken into consideration. Several measurements have been executed to determine the optimal positioning of a sensor under the mattress to obtain a signal strong enough for further analysis. A prototype for an unobtrusive accelerometer-based measurement system has been developed and tested in a conventional bed without any specific extras. The influence of the human sleep position for the output accelerometer data was tested. The obtained results indicate the potential to capture BCG signals using accelerometers. The measurement system can detect heart rate in an unobtrusive form in the home environment.
The main aim of presented in this manuscript research is to compare the results of objective and subjective measurement of sleep quality for older adults (65+) in the home environment. A total amount of 73 nights was evaluated in this study. Placing under the mattress device was used to obtain objective measurement data, and a common question on perceived sleep quality was asked to collect the subjective sleep quality level. The achieved results confirm the correlation between objective and subjective measurement of sleep quality with the average standard deviation equal to 2 of 10 possible quality points.
Good sleep is crucial for a healthy life of every person. Unfortunately, its quality often decreases with aging. A common approach to measuring the sleep characteristics is based on interviews with the subjects or letting them fill in a daily questionnaire and afterward evaluating the obtained data. However, this method has time and personal costs for the interviewer and evaluator of responses. Therefore, it would be important to execute the collection and evaluation of sleep characteristics automatically. To do that, it is necessary to investigate the level of agreement between measurements performed in a traditional way using questionnaires and measurements obtained using electronic monitoring devices. The study presented in this manuscript performs this investigation, comparing such sleep characteristics as "time going to bed", "total time in bed", "total sleep time" and "sleep efficiency". A total number of 106 night records of elderly persons (aged 65+) were analyzed. The results achieved so far reveal the fact that the degree of agreement between the two measurement methods varies substantially for different characteristics, from 31 minutes of mean difference for "time going to bed" to 77 minutes for "total sleep time". For this reason, a direct exchange of objective and subjective measuring methods is currently not possible.
Polysomnography is a gold standard for a sleep study, and it provides very accurate results, but its cost (both personnel and material) are quite high. Therefore, the development of a low-cost system for overnight breathing and heartbeat monitoring, which provides more comfort while recording the data, is a well-motivated challenge. The system proposed in this manuscript is based on the usage of resistive pressure sensors installed under the mattress. These sensors can measure slight pressure changes provoked during breathing and heartbeat. The captured signal requires advanced processing, like applying filters and amplifiers before the analog signal is ready for the next step. Then, the output signal is digitalized and further processed by an algorithm that performs a custom filtering before it can recognize breathing and heart rate in real-time. The result can be directly visualized. Furthermore, a CSV file is created containing the raw data, timestamps, and unique IDs to facilitate further processing. The achieved results are promising, and the average deviation from a reference device is about 4bpm.