Refine
Year of publication
- 2017 (32) (remove)
Document Type
- Article (32) (remove)
Has Fulltext
- no (32)
Keywords
- Bernstein coefficient (2)
- Compliance (1)
- ECG (1)
- Elektromagnete (1)
- End-user computing (1)
- Entry-wise perturbation (1)
- Fassade (1)
- Fassadensanierung (1)
- Health care (1)
- Heart rate (1)
A real matrix is called totally nonnegative if all of its minors are nonnegative. In this paper, the minors are determined from which the maximum allowable entry perturbation of a totally nonnegative matrix can be found, such that the perturbed matrix remains totally nonnegative. Also, the total nonnegativity of the first and second subdirect sum of two totally nonnegative matrices is considered.
Sensorlose Positionsregelung eines hydraulischen Proportional-Wegeventils mittels Signalinjektion
(2017)
Es wird eine Methode zur sensorlosen Positionsbestimmung bei elektromagnetisch betätigten Aktoren vorgestellt. Dabei werden basierend auf einer Signalinjektion die positionsabhängigen Parameter bei der injizierten Frequenz bestimmt und daraus über ein geeignetes Modell die Position des Magnetankers ermittelt. Die Eignung des Verfahrens zur sensorlosen Positionsregelung wird an einem bidirektionalen Proportionalventil anhand praktischer Versuche demonstriert.
Ulrich Finsterwalder
(2017)
A flight-like absolute optical frequency reference based on iodine for laser systems at 1064 nm
(2017)
We present an absolute optical frequency reference based on precision spectroscopy of hyperfine transitions in molecular iodine 127I2 for laser systems operating at 1064 nm. A quasi-monolithic spectroscopy setup was developed, integrated, and tested with respect to potential deployment in space missions that require frequency stable laser systems. We report on environmental tests of the setup and its frequency stability and reproducibility before and after each test. Furthermore, we report on the first measurements of the frequency stability of the iodine reference with an unsaturated absorption cell which will greatly simplify its application in space missions. Our frequency reference fulfills the requirements on the frequency stability for planned space missions such as LISA or NGGM.
This work proposes a lossless data compression algorithm for short data blocks. The proposed compression scheme combines a modified move-to-front algorithm with Huffman coding. This algorithm is applicable in storage systems where the data compression is performed on block level with short block sizes, in particular, in non-volatile memories. For block sizes in the range of 1(Formula presented.)kB, it provides a compression gain comparable to the Lempel–Ziv–Welch algorithm. Moreover, encoder and decoder architectures are proposed that have low memory requirements and provide fast data encoding and decoding.
Zur Rhetorik der Technik
(2017)
Compliance Essentials
(2017)
Rethinking Compliance
(2017)
In the past Compliance Management has often failed, the Volkswagen emissions scandal just being one prominent example. Not everything has to be reinvented, and not everything that companies have done in the past regarding Compliance is wrong. But it is about time to think Compliance in new ways. What does “Compliance Management 2.0” really depend on? The following article aims at laying out the cornerstones for enduring effective Compliance which amongst others comprises sincerity and credibility and a moral foundation. Furthermore, the commitment and role model behavior of top managers and the training of line managers are crucial for the effectiveness of any Compliance Management System (CMS). Ultimately, for Compliance to function efficiently the efforts must be adequate for the respective company and realistic regarding the achievable goals.