Adjusting the friction response of the wheel-rail interface is a key factor in the mitigation of wear and rollingcontact fatigue (RCF) in rails. The use of top-of-rail (TOR) friction conditioners has the potential to reduce maintenance costs significantly. Unfortunately, conflicting results on the use of commercial TOR conditioners have been presented in the literature. In this work, the performance of commercial TOR conditioners and a laboratory-made formulation were tested, both on the lab scale and in field measurements. Friction results are discussed together with the structural and chemical analysis of the tested materials.
Pitting susceptibility of metastable austenitic stainless steels as a function of surface conditions
(2019)
The influence of surface roughness and local defects on pitting susceptibility of type 304 (UNS S30400) and type 301 (UNS S30100) in chloride solution were investigated. Because the mechanical properties can be regarded as decisive for the achieved surface quality, different properties of the base material were obtained by cold rolling the metastable austenites. This was done before the surfaces were finished. Therefor the surfaces were treated by different grinding parameters to generate different surface conditions and different defects. As a reference, different standardised surface finishes were used.
By using and comparing different methods for the characterization of surface roughness and surface texture, it is possible to find a relationship between the quantity and characteristics of local defects on the one hand and pitting susceptibility on the other hand. For the machining parameters used, a ranking of the influencing factors on the corrosion resistance achieved could be determined.
The automated application of software-based solutions for estimating the pitting susceptibility of machined surfaces and components will be discussed using concrete examples.
Pitting susceptibility of metastable austenitic stainless steels as a function of surface conditions
(2019)
Fachvortrag auf der 10th International European Stainless Steel Conference and 6th European Duplex Stainless Steel Conference (ESSC & DUPLEX 2019), 30.09. – 02.10.2019, Vienna, Austria
This paper compares the surface morphology of differently finished austenitic stainless steel AISI 316L, also in combination with low temperature carburization. Milled and tumbled surfaces were analyzed by means of corrosion resistance and surface morphology. The results of potentiodynamic measurements show that professional grinding operations with SiC and Al2O3 always lead to a better corrosion resistance of low temperature carburized surfaces compared to the untreated reference in the used acidified chloride solution. Big influence on the corrosion resistance of vibratory ground or tumbled surfaces has the amount of plastic deformation while machining, that has to be kept low for austenitic stainless steels. Due to the high ductility, plastic deformation can lead to the formation of meta stable pits that can be initiation points of corrosion. The formation of meta stable pits can be aggravated by low temperature diffusion processes.
Hot isostatic pressing (HIP) allows the production of complex components geometry. Generally, a high quality of the components is achieved due to the well managed composition of the metal powder and the non-isotropic properties. If a duplex stainless steel is produced, a heat treatment after the HIP-process is necessary to remove precipitations like carbides, nitrides and intermetallic phases. In a new process, the sintering step should be combined with the heat treatment. In this case a high cooling rate is necessary to avoid precipitations in duplex stainless steels. In this work, the influence of the HIP-temperature and the wall thickness on corrosion resistance, microstructure and impact strength were investigated. The results should help to optimize the process parameters like temperature and cooling rate. For the investigation, two HIP-temperatures were tested in a classical HIP-process step with a defined cooling rate. An additional heat treatment was not conducted. The specimens were cut from different sectors of the HIP-block. For investigation of the corrosion resistance, the critical pitting temperature was determined with electrochemical method according to EN ISO 17864. An impact test was used to determine the impact transition temperature. Metallographic investigations show the microstructure in the different sectors of the HIP-block.
The electrochemical behavior for different surface conditions and different degrees of deformation of metastable austenitic stainless steel AISI 304 UNS S30400 were studied using critical pitting potential and electrochemical noise measurements. The influence on corrosion resistance by using different abrasives (silicon carbide and corundum) for surface finish by grinding is illustrated. For the characterization of local defects and surface topography, scanning electron microscopy (SEM) and tactile measurements were used. An inverse correlation between occurrence of local defects on the surface and critical pitting potential was found by using image processing. Therefore, gray scale values of different surfaces were compared. The influence of mass content of α'-martensite on the corrosion resistance is shown by comparing different qualities of surface finish. For smooth machined surfaces it can be shown that an increasing numbers of strain induced martensite is decreasing the corrosion resistance lightly. For low abrasive machining an inverse correlation between the critical pitting potential and surface roughness is given. However, for higher abrasive machining parameters, this correlation could not be found.