With the advancement in sensor technology and the trend shift of health measurement from treatment after diagnosis to abnormalities detection long before the occurrence, the approach of turning private spaces into diagnostic spaces has gained much attention. In this work, we designed and implemented a low-cost and compact form factor module that can be deployed on the steering wheel of cars as well as most frequently touch objects at home in order to measure physiological signals from the fingertip of the subject as well as environmental parameters. We estimated the heart rate and SpO2 with the error of 2.83 bpm and 3.52%, respectively. The signal evaluation of skin temperature shows a promising output with respect to environmental recalibration. In addition, the electrodermal activity sensor followed the reference signal, appropriately which indicates the potential for further development and application in stress measurement.
The perception of the amount of stress is subjective to every person, and the perception of it changes depending on many factors. One of the factors that has an impact on perceived stress is the emotional state. In this work, we compare the emotional state of 40 German driving students and present different partitions that can be advantageous for using artificial intelligence and classification. Like this, we evaluate the data quality and prepare for the specific use. The Stress Perceived Questionnaire (PSQ20) was employed to assess the level of stress experienced by individuals while participating in a driving simulation for 5 and 25 min. As a result of our analysis, we present a categorisation of various emotional states into intervals, comparing different classifications and facilitating a more straightforward implementation of artificial intelligence for classification purposes.
Evaluation of a Contactless Accelerometer Sensor System for Heart Rate Monitoring During Sleep
(2024)
The monitoring of a patient's heart rate (HR) is critical in the diagnosis of diseases. In the detection of sleep disorders, it also plays an important role. Several techniques have been proposed, including using sensors to record physiological signals that are automatically examined and analysed. This work aims to evaluate using a contactless HR monitoring system based on an accelerometer sensor during sleep. For this purpose, the oscillations caused by chest movements during heart contractions are recorded by an installation mounted under the bed mattress. The processing algorithm presented in this paper filters the signals and determines the HR. As a result, an average error of about 5 bpm has been documented, i.e., the system can be considered to be used for the forecasted domain.
Sleep is extremely important for physical and mental health. Although polysomnography is an established approach in sleep analysis, it is quite intrusive and expensive. Consequently, developing a non-invasive and non-intrusive home sleep monitoring system with minimal influence on patients, that can reliably and accurately measure cardiorespiratory parameters, is of great interest. The aim of this study is to validate a non-invasive and unobtrusive cardiorespiratory parameter monitoring system based on an accelerometer sensor. This system includes a special holder to install the system under the bed mattress. The additional aim is to determine the optimum relative system position (in relation to the subject) at which the most accurate and precise values of measured parameters could be achieved. The data were collected from 23 subjects (13 males and 10 females). The obtained ballistocardiogram signal was sequentially processed using a sixth-order Butterworth bandpass filter and a moving average filter. As a result, an average error (compared to reference values) of 2.24 beats per minute for heart rate and 1.52 breaths per minute for respiratory rate was achieved, regardless of the subject’s sleep position. For males and females, the errors were 2.28 bpm and 2.19 bpm for heart rate and 1.41 rpm and 1.30 rpm for respiratory rate. We determined that placing the sensor and system at chest level is the preferred configuration for cardiorespiratory measurement. Further studies of the system’s performance in larger groups of subjects are required, despite the promising results of the current tests in healthy subjects.
Das klinische Standardverfahren und Referenz der Schlafmessung und der Klassifizierung der einzelnen Schlafstadien ist die Polysomnographie (PSG). Alternative Ansätze zu diesem aufwändigen Verfahren könnten einige Vorteile bieten, wenn die Messungen auf eine komfortablere Weise durchgeführt werden. Das Hauptziel dieser Forschung Studie ist es, einen Algorithmus für die automatische Klassifizierung von Schlafstadien zu entwickeln, der ausschließlich Bewegungs- und Atmungssignale verwendet.
Sleep is a multi-dimensional influencing factor on physical health, cognitive function, emotional well-being, mental health, daily performance, and productivity. The barriers such as time-consuming, invasiveness, and expense have caused a gradual shift in sleep monitoring from traditional and standard in-lab approach, e. g., polysomnography (PSG) to unobtrusive and noninvasive in-home sleep monitoring, yet further improvement is required. Despite an increasing interest in fiberoptic-based methods for cardiorespiratory estimation, the traditional mechanical-based sensors consist of force-sensitive resistors (FSR), lead zirconate titanate piezoelectric (PZT), and accelerometers yet serve as the dominant approach. The part of popularity lies in reducing the system’s complexity, expense, easy maintenance, and user-friendliness. However, care must be taken regarding the performance of such sensors with respect to accuracy and calibration.
The development of automatic solutions for the detection of physiological events of interest is booming. Improvements in the collection and storage of large amounts of healthcare data allow access to these data faster and more efficiently. This fact means that the development of artificial intelligence models for the detection and monitoring of a large number of pathologies is becoming increasingly common in the medical field. In particular, developing deep learning models for detecting obstructive apnea (OSA) events is at the forefront. Numerous scientific studies focus on the architecture of the models and the results that these models can provide in terms of OSA classification and Apnea-Hypopnea-Index (AHI) calculation. However, little focus is put on other aspects of great relevance that are crucial for the training and performance of the models. Among these aspects can be found the set of physiological signals used and the preprocessing tasks prior to model training. This paper covers the essential requirements that must be considered before training the deep learning model for obstructive sleep apnea detection, in addition to covering solutions that currently exist in the scientific literature by analyzing the preprocessing tasks prior to training.
Development of an expert system to overpass citizens technological barriers on smart home and living
(2023)
Adopting new technologies can be overwhelming, even for people with experience in the field. For the general public, learning about new implementations, releases, brands, and enhancements can cause them to lose interest. There is a clear need to create point sources and platforms that provide helpful information about the novel and smart technologies, assisting users, technicians, and providers with products and technologies. The purpose of these platforms is twofold, as they can gather and share information on interests common to manufacturers and vendors. This paper presents the ”Finde-Dein-SmartHome” tool. Developed in association with the Smart Home & Living competence center [5] to help users learn about, understand, and purchase available technologies that meet their home automation needs. This tool aims to lower the usability barrier and guide potential customers to clear their doubts about privacy and pricing. Communities can use the information provided by this tool to identify market trends that could eventually lower costs for providers and incentivize access to innovative home technologies and devices supporting long-term care.