This paper compares the surface morphology of differently finished austenitic stainless steel AISI 316L, also in combination with low temperature carburization. Milled and tumbled surfaces were analyzed by means of corrosion resistance and surface morphology. The results of potentiodynamic measurements show that professional grinding operations with SiC and Al2O3 always lead to a better corrosion resistance of low temperature carburized surfaces compared to the untreated reference in the used acidified chloride solution. Big influence on the corrosion resistance of vibratory ground or tumbled surfaces has the amount of plastic deformation while machining, that has to be kept low for austenitic stainless steels. Due to the high ductility, plastic deformation can lead to the formation of meta stable pits that can be initiation points of corrosion. The formation of meta stable pits can be aggravated by low temperature diffusion processes.