Refine
Year of publication
Document Type
- Conference Proceeding (43)
- Article (7)
- Master's Thesis (5)
- Report (4)
- Bachelor Thesis (1)
- Doctoral Thesis (1)
- Other Publications (1)
- Working Paper (1)
Language
- English (63) (remove)
Keywords
Institute
- Fakultät Informatik (63) (remove)
This thesis investigates methods for the recognition of facial expressions using support vector machines. Rather than trying to recognize facial actions in the face such as raised eyebrow, mouth open and frowns. These facial actions are described in the Facial Action Coding System (FACS) and are essential facial components, which can be combined to form facial expressions. We perform independent recognition of 6 upper and 10 lower action units in the face, which may occur either individually or in combination. Based on a feature extraction from grey-level values, the system is expected to recognize under real-time conditions. Results are presented with different image resolutions, SVM kernels and variations of low-level features.
The target of this thesis is the introduction of a client management system (CMS) at Haaland Internet Productions (HiP), a web design and hosting company in Burbank, California, USA. The company needs a system to track orders and improve workflow. HiP needs a system which not only tracks orders, but also stores all client information in a database. This client information can be used for a variety of marketing and contact reasons. It is an important and integral part of HiP's client relationship management (CRM). The lack of a cohesive CMS at HiP caused many fundamental business problems, such as lost orders, missed billing statements, and over/under billing. The research done during the investigation and analysis of the company and their needs should lead to a global system which totally fulfils the needs of HiP. This global system could be in the form of an off-the-shelf product with some customizations, or a completely new, in-house system. Either solution will have respective pros and cons; the goal is to reach a decision that best fits HiP's needs and situation. The following is a concise version of the project. Particular emphasis is placed upon the single steps which made up the decision process, as well as the practiced techniques, methods, and their applications.
This thesis deals with background, theory, design, layout and experimental test results of an analogue CMOS VLSI current-mode analog-to-digital converter. This system supports a project, whose goal it is to build a biologically relevant model of synaptic plasticity, named the Artificial Synapse. A critical part of the design, which is based on analogue CMOS VLSI circuits, is the ability to activate a discrete number of channels by sampling an analogue signal. Since currents are the signal of interest and transistors are biased in weak inversion (subthreshold regime), the system requires a current mode A/D circuit that it can operate at ultra-low power and current levels. To meet this need, two new innovative A/D converter approaches are proposed to replace the system’s previous A/D converter design which suffered from a non-linear resolution, uncoded output code and heavy bit oscillations. The initial technical requirements and key criteria for the new converter comprise a resolution of one nano ampere, an input current range between 0 – 100nA, conversion frequencies of up to 5kHz, and a power supply voltage of less than 1.5V. Temperature range, space occupation and power dissipation aspects were not specified due to the early stage of the related Artificial Synapse project. The novel converters both produce seven bit thermometer codes, their functional principle can be best described as current mode flash analog-to-digital converters (ADCs). Due to the fact that the input signal is in the area of a subthreshold current, it is selfevident that the A/D converter design should operate at a subthreshold realm. To support low power operation, clocks or high currents could not be used and were excluded from the design from the very start. To encode the thermometer code into standard binary code, a seven-to-three encoder was designed and integrated on the chip. In October 2003, the design was submitted for production to the MOSIS circuit fabrication service. The AMI Semiconductor 1.5 micron ABN CMOS process was chosen to manufacture the chip. When it was returned in January 2004, simulation results showed that both new A/D converter approaches accomplished excellent results which were expected from SPICE simulation results. With the new chip installed, it became possible to resolve input currents as small as one nano ampere and achieve conversion frequencies of up to 5kHz. The circuits also both meet the requirements which were set at the beginning of the project to operate at a power supply voltage of less than 1.5V, processing input currents in the range between 0 – 100nA. A prototype printed circuit board (PCB) was developed, produced and employed for experiments with the chip. The major application of this test-bed is the ability to generate and measure extremely low currents with high precision. This enables the monitoring of the very small currents that are processed by the chip.
This work treats with the segmentation of 2D environment Laser data, captured by an Autonomous Mobile Indoor Robot. It is part of the data processing, which is necessary to navigate a mobile robot error free in its environment. The whole process can generally be described by data capturing, data processing and navigation. In this project the data processing deals with data, captured by a Laser-Sensor, which provides two dimensional data by a series of distance measurements i.e. point-measurements of the environment. These point series have to be filtered and processed into a more convenient representation to provide a virtual environment map, which can be used of the robot for an error free navigation. This project provides different solutions of the same problem: the conversion from distance points to model segments which should represent the real world environment as close as possible. The advantages and disadvantages of each of the different Segmentation-Algorithms will be shown as well as a comparison taking into account the Computational Time and the Robustness of the results.
Web services are, due to the excellent tool support, simple to provide and use in trivial cases. But their use in non-trivial Web service-based systems like I3M poses new difficulties and problems. I3M is an instant messaging and chat system with distributed and local components collaborating via Web services. One difficulty is to make a series of related Web service invocations in a stateful session. A problem is the performance of collaborating collocated, service-oriented components of a system due to the high Web service invocation overheaed as is shown by measurements. Solutions to both the difficulty and the problem are proposed.
Sleep quality and in general, behavior in bed can be detected using a sleep state analysis. These results can help a subject to regulate sleep and recognize different sleeping disorders. In this work, a sensor grid for pressure and movement detection supporting sleep phase analysis is proposed. In comparison to the leading standard measuring system, which is Polysomnography (PSG), the system proposed in this project is a non-invasive sleep monitoring device. For continuous analysis or home use, the PSG or wearable Actigraphy devices tends to be uncomfortable. Besides this fact, they are also very expensive. The system represented in this work classifies respiration and body movement with only one type of sensor and also in a non-invasive way. The sensor used is a pressure sensor. This sensor is low cost and can be used for commercial proposes. The system was tested by carrying out an experiment that recorded the sleep process of a subject. These recordings showed the potential for classification of breathing rate and body movements. Although previous researches show the use of pressure sensors in recognizing posture and breathing, they have been mostly used by positioning the sensors between the mattress and bedsheet. This project however, shows an innovative way to position the sensors under the mattress.
This paper presents a bed system able to analyze a person’s movement, breathing and recognize the positions that the subject is lying on the bed during the night without any additional physical contact. The measurements are performed with sensors placed between the mattress and the bed-frame. An Intel Edison board was used as an endpoint that served as a communication node from the mesh network to external service. Two nodes and Intel Edison are attached to the bottom of the bed frame and they are connected to the sensors. First test results have indicated the potential of the proposed approach for the recognition of sleep positions with 83% of correct recognized positions.
The overall goal of this work is to detect and analyze a person's movement, breathing and heart rate during sleep in a common bed overnight without any additional physical contact. The measurement is performed with the help of
sensors placed between the mattress and the frame. A two-stage pattern classification algorithm based has been implemented that applies statistics analysis to recognize the position of patients. The system is implemented in a sensors-network, hosting several nodes and communication end-points to support quick and efficient classification. The overall tests show convincing results for the position recognition and a reasonable overlap in matching.
Sleep study can be used for detection of sleep quality and in general bed behaviors. These results can helpful for regulating sleep and recognizing different sleeping disorders of human. In comparison to the leading standard measuring system, which is Polysomnography (PSG), the system proposed in this work is a non-invasive sleep monitoring device. For continuous analysis or home use, the PSG or wearable Actigraphy devices tends to be uncomfortable. Besides, these methods not only decrease practicality due to the process of having to put them on, but they are also very expensive. The system proposed in this paper classifies respiration and body movement with only one type of sensor and also in a noninvasive way. The sensor used is a pressure sensor. This sensor is low cost and can be used for commercial proposes. The system was tested by carrying out an experiment that recorded the sleep process of a subject. These recordings showed excellent results in the classification of breathing rate and body movements.
Long-term sleep monitoring can be done primarily in the home environment. Good patient acceptance requires low user and installation barriers. The selection of parameters in this approach is significantly limited compared to a PSG session. The aim is a qualified selection of parameters, which on the one hand allow a sufficiently good classification of sleep phases and on the other hand can be detected by non-invasive methods.
The process of restoring our body and brain from fatigue is directly depend-ing on the quality of sleep. It can be determined from the report of the sleep study results. Classification of sleep stages is the first step of this study and this includes the measurement of biovital data and its further processing.
In this work, the sleep analysis system is based on a hardware sensor net, namely a grid of 24 pressure sensors, supporting sleep phase recognition. In comparison to the leading standard, which is polysomnography, the proposed approach is a non-invasive system. It recognises respiration and body move-ment with only one type of low-cost pressure sensors forming a mesh archi-tecture. The nodes implement as a series of pressure sensors connected to a low-power and performant microcontroller. All nodes are connected via a system wide bus with address arbitration. The embedded processor is the mesh network endpoint that enables network configuration, storing and pre-processing of the data, external data access and visualization.
The system was tested by executing experiments recording the sleep of different healthy young subjects. The results obtained have indicated the po-tential to detect breathing rate and body movement. A major difference of this system in comparison to other approaches is the innovative way to place the sensors under the mattress. This characteristic facilitates the continuous using of the system without any influence on the common sleep process.
Objective: This paper presents an algorithm for non-invasive sleep stage identification using respiratory, heart rate and movement signals. The algorithm is part of a system suitable for long-term monitoring in a home environment, which should support experts analysing sleep. Approach: As there is a strong correlation between bio-vital signals and sleep stages, multinomial logistic regression was chosen for categorical distribution of sleep stages. Several derived parameters of three signals (respiratory, heart rate and movement) are input for the proposed method. Sleep recordings of five subjects were used for the training of a machine learning model and 30 overnight recordings collected from 30 individuals with about 27 000 epochs of 30 s intervals each were evaluated. Main results: The achieved rate of accuracy is 72% for Wake, NREM, REM (with Cohen's kappa value 0.67) and 58% for Wake, Light (N1 and N2), Deep (N3) and REM stages (Cohen's kappa is 0.50). Our approach has confirmed the potential of this method and disclosed several ways for its improvement. Significance: The results indicate that respiratory, heart rate and movement signals can be used for sleep studies with a reasonable level of accuracy. These inputs can be obtained in a non-invasive way applying it in a home environment. The proposed system introduces a convenient approach for a long-term monitoring system which could support sleep laboratories. The algorithm which was developed allows for an easy adjustment of input parameters that depend on available signals and for this reason could also be used with various hardware systems.
We identify 74 generic, reusable technical requirements based on the GDPR that can be applied to software products which process personal data. The requirements can be traced to corresponding articles and recitals of the GDPR and fulfill the key principles of lawfulness and transparency. Therefore, we present an approach to requirements engineering with regard to developing legally compliant software that satisfies the principles of privacy by design, privacy by default as well as security by design.
To get a better understanding of Cross Site Scripting vulnerabilities, we investigated 50 randomly selected CVE reports which are related to open source projects. The vulnerable and patched source code was manually reviewed to find out what kind of source code patterns were used. Source code pattern categories were found for sources, concatenations, sinks, html context and fixes. Our resulting categories are compared to categories from CWE. A source code sample which might have led developers to believe that the data was already sanitized is described in detail. For the different html context categories, the necessary Cross Site Scripting prevention mechanisms are described.
We investigated 50 randomly selected buffer overflow vulnerabilities in Firefox. The source code of these vulnerabilities and the corresponding patches were manually reviewed and patterns were identified. Our main contribution are taxonomies of errors, sinks and fixes seen from a developer's point of view. The results are compared to the CWE taxonomy with an emphasis on vulnerability details. Additionally, some ideas are presented on how the taxonomy could be used to improve the software security education.
This document presents an algorithm for a non-obtrusive recognition of Sleep/Wake states using signals derived from ECG, respiration, and body movement captured while lying in a bed. As a core mathematical base of system data analytics, multinomial logistic regression techniques were chosen. Derived parameters of the three signals are used as the input for the proposed method. The overall achieved accuracy rate is 84% for Wake/Sleep stages, with Cohen’s kappa value 0.46. The presented algorithm should support experts in analyzing sleep quality in more detail. The results confirm the potential of this method and disclose several ways for its improvement.
A significant proportion of road traffic accidents are due to inattentiveness or fatigue at the wheel. Approaches to monitoring the driver's condition range from eye tracking and driving behavior analysis to yawn and blink detection and ECG measurement. This work describes the development of a mobile system for the measurement and processing of ECG data. The aim of the signal processing is to quantify the driver’s fatigue with the heartrate variability (HRV). The work includes the hardware and software design of the sensor. First, the development of low-noise electronics including AD conversion is described. Then the software signal processing with QRS complex detection and plotting front end is explained. The resulting sensor is compact, low-cost and provides a good signal for HRV extraction.
The investigation of stress requires to distinguish between stress caused by physical activity and stress that is caused by psychosocial factors. The behaviour of the heart in response to stress and physical activity is very similar in case the set of monitored parameters is reduced to one. Currently, the differentiation remains difficult and methods which only use the heart rate are not able to differentiate between stress and physical activity, without using additional sensor data input. The approach focusses on methods which generate signals providing characteristics that are useful for detecting stress, physical activity, no activity and relaxation.
The exposure to the light has a great influence on human beings in their everyday life. Various lighting sources produce light that reaches the human eye and influences a rhythmic release of melatonin hormone, that is a sleep promoting factor.
Since the development of new technologies provides more control over illuminance, this work uses an IoT based lighting system to set up dim and bright scenarios. A small study has been performed on the influence of illuminance on sleep latency. The system consists of different light bulbs, sensors and a central bridge which are interconnected like a mesh network. Also, a mobile app has been developed, that allows to adjust the lighting in various rooms. With the help of a ferro-electret sensor, like applied in sleep monitoring systems, a subject’s sleep was monitored. The sensor is placed below the mattress and it collects data, which is stored and processed in a cloud or in other alternative locations.
The research was conducted on healthy young subjects after being previously exposed to the preconfigured illuminance for at least three hours before bedtime. The results indicate correlation between sleep onset latency and exposure to different illuminance before bedtime. In a dimmed environment, the subject fell asleep in average 28% faster compared to the brighter environment.
The number of home office workers sitting for many hours is increasing. The sensor chair is tracking users’ sitting behavior which the help of pressure sensors and tries to avoid wrong postures which may cause diseases. The system provides live monitoring of the pressure distribution via web interface, as well as sitting posture prediction in real time. Posture analysis is realized through machine learning algorithm using a decision tree classifier that is compared to a random forest. Data acquisition and aggregation for the learning process happens with a mobile app adding users biometrical data and the taken sitting posture as label. The sensor chair is able to differentiate between an arched back, a neutral posture or a laid back position taken on the chair. The classifier achieves an accuracy of 97.4% on our test set and is comparable to the performance of the random forest with 98.9%.
The Industrial Internet of Things (IIoT) will leverage on wireless network technologies to integrate in a seamless manner Cyber-Physical Systems into existing information systems. In this context, the 6TiSCH architecture, proposed by IETF, represents the current leading standardization effort to enable timed and reliable data communication within IPv6 networks for industrial applications. In wireless networks, Link Quality Estimation (LQE) is a crucial task to select the best routes for data forwarding, regardless of unpredictable time varying conditions. Although, many solutions for LQE have been proposed in literature, the majority of them are not designed specifically for 6TiSCH networks. In this paper, we analyze the performance of existing LQE strategies on 6TiSCH networks.
First, we run a set of simulations to measure the performance of one existing LQE strategy in 6TiSCH. Our simulations show that such strategy can result in measurements with low accuracy due to the 6TiSCH default timeslot allocation strategy. Consequently, we propose an extension of the 6TiSCH Minimal Configuration that allocates specific timeslots for the transmission of probing messages to mitigate the problem. The proposed methodology is demonstrated to effectively reduce the LQE error.
The cornerstone of cognitive systems is environment awareness which enables agile and adaptive use of channel resources. Whitespace prediction based on learning the statistics of the wireless traffic has proven to be a powerful tool to achieve such awareness. In this paper, we propose a novel Hidden Markov Model (HMM) based spectrum learning and prediction approach which accurately estimates the exact length of the whitespace in WiFi channels within the shared industrial scientific medical ISM) bands. We show that extending the number of hidden states and formulating the prediction problem as a maximum likelihood (ML) classification leads to a substantial increase in the prediction horizon compared to classical approaches that predict the immediate (short-term) future. We verify the proposed algorithm through simulations which utilize a model for WiFi traffic based on extensive measurement campaigns.
The goal of the presented project is to develop the concept of home ehealth centers for barrier-free and cross-border telemedicine. AAL technologies are already present on the market but there is still a gap to close until they can be used for ordinary patient needs. The general idea needs to be accompanied by new services, which should be brought together in order to provide a full coverage of service for the users. Sleep and stress were chosen as predominant diseases for a detailed study within this project because of their widespread influence in the population. The executed scientific study of available home devices analyzing sleep has provided the necessary to select appropriate devices. The first choice for the project implementation is the device EMFIT QS+. This equipment provides a part of a complete system that a home telemedical hospital can provide at a level of precision and communication with internal and/or external health services.
Fatigue and drowsiness are responsible for a significant percentage of road traffic accidents. There are several approaches to monitor the driver’s drowsiness, ranging from the driver’s steering behavior to analysis of the driver, e.g. eye tracking, blinking, yawning or electrocardiogram (ECG). This paper describes the development of a low-cost ECG sensor to derive heart rate variability (HRV) data for the drowsiness detection. The work includes the hardware and the software design. The hardware has been implemented on a printed circuit board (PCB) designed so that the board can be used as an extension shield for an Arduino. The PCB contains a double, inverted ECG channel including low-pass filtering and provides two analog outputs to the Arduino, that combined them and performs the analog-to-digital conversion. The digital ECG signal is transferred to an NVidia embedded PC where the processing takes place, including QRS-complex, heart rate and HRV detection as well as visualization features. The compact resulting sensor provides good results in the extraction of the main ECG parameters. The sensor is being used in a larger frame, where facial-recognition-based drowsiness detection is combined with ECG-based detection to improve the recognition rate under unfavorable light or occlusion conditions.
The IETF, concerned with the evolution of the Internet architecture, nowadays also looks into industrial automation processes. The contributions of a variety of IETF activities, initiated during the last ten years, enable now the replacement of proprietary standards by an open standardized protocol stack. This stack, denoted in the following as 6TiSCH-stack, is tailored for industrial internet of things (IIoTs). The suitability of 6TiSCH-stack for Industry 4.0 is yet to explore. In this paper, we identify four challenges that, in our opinion, may delay or hinder its adoption. As a prime example of that, we focus on the initial 6TiSCHnetwork
formation, highlighting the shortcomings of the default procedure and introducing our current work for a fast and reliable formation of dense network.
The recovery of our body and brain from fatigue directly depends on the quality of sleep, which can be determined from the results of a sleep study. The classification of sleep stages is the first step of this study and includes the measurement of vital data and their further processing. The non-invasive sleep analysis system is based on a hardware sensor network of 24 pressure sensors providing sleep phase detection. The pressure sensors are connected to an energy-efficient microcontroller via a system-wide bus. A significant difference between this system and other approaches is the innovative way in which the sensors are placed under the mattress. This feature facilitates the continuous use of the system without any noticeable influence on the sleeping person. The system was tested by conducting experiments that recorded the sleep of various healthy young people. Results indicate the potential to capture respiratory rate and body movement.
In my research sabbatical I was working on three different topics, namely orthogonal polynomials in geometric modeling, re-parametrized univariate subdivision curves, and reconstruction of 3d-fish-models and other zoological artifacts. In the subsequent Sections, I will describe my particular activity in these different fields. The sections are meant to present an overview of my research activities, leaving out the technical details.
Section 1 is on orthogonal polynomials and other related generating systems for functions systems of smooth function.
In Section 2, I will discuss the application of various re-parametrization schemes for interpolatory subdivision algorithms for the generation of space curves.
The next Section 3 is concerned with my research at the University of Queensland, Brisbane, in collaboration with Dr. Ulrike Siebeck from the School of Biomedical Sciences on fish behavior and reconstruction of 3d-fish models in particular.
In the last Section 4, I will describe what effects this research will have on in my subsequent teaching at the University of Applied Science Konstanz (HTWG).
Polysomnography is a gold standard for a sleep study, and it provides very accurate results, but its cost (both personnel and material) are quite high. Therefore, the development of a low-cost system for overnight breathing and heartbeat monitoring, which provides more comfort while recording the data, is a well-motivated challenge. The system proposed in this manuscript is based on the usage of resistive pressure sensors installed under the mattress. These sensors can measure slight pressure changes provoked during breathing and heartbeat. The captured signal requires advanced processing, like applying filters and amplifiers before the analog signal is ready for the next step. Then, the output signal is digitalized and further processed by an algorithm that performs a custom filtering before it can recognize breathing and heart rate in real-time. The result can be directly visualized. Furthermore, a CSV file is created containing the raw data, timestamps, and unique IDs to facilitate further processing. The achieved results are promising, and the average deviation from a reference device is about 4bpm.
Good sleep is crucial for a healthy life of every person. Unfortunately, its quality often decreases with aging. A common approach to measuring the sleep characteristics is based on interviews with the subjects or letting them fill in a daily questionnaire and afterward evaluating the obtained data. However, this method has time and personal costs for the interviewer and evaluator of responses. Therefore, it would be important to execute the collection and evaluation of sleep characteristics automatically. To do that, it is necessary to investigate the level of agreement between measurements performed in a traditional way using questionnaires and measurements obtained using electronic monitoring devices. The study presented in this manuscript performs this investigation, comparing such sleep characteristics as "time going to bed", "total time in bed", "total sleep time" and "sleep efficiency". A total number of 106 night records of elderly persons (aged 65+) were analyzed. The results achieved so far reveal the fact that the degree of agreement between the two measurement methods varies substantially for different characteristics, from 31 minutes of mean difference for "time going to bed" to 77 minutes for "total sleep time". For this reason, a direct exchange of objective and subjective measuring methods is currently not possible.
The evaluation of the effectiveness of different machine learning algorithms on a publicly available database of signals derived from wearable devices is presented with the goal of optimizing human activity recognition and classification. Among the wide number of body signals we choose a couple of signals, namely photoplethysmographic (optically detected subcutaneous blood volume) and tri-axis acceleration signals that are easy to be simultaneously acquired using commercial widespread devices (e.g. smartwatches) as well as custom wearable wireless devices designed for sport, healthcare, or clinical purposes. To this end, two widely used algorithms (decision tree and k-nearest neighbor) were tested, and their performance were compared to two new recent algorithms (particle Bernstein and a Monte Carlo-based regression) both in terms of accuracy and processing time. A data preprocessing phase was also considered to improve the performance of the machine learning procedures, in order to reduce the problem size and a detailed analysis of the compression strategy and results is also presented.
This paper presents the implementation of deep learning methods for sleep stage detection by using three signals that can be measured in a non-invasive way: heartbeat signal, respiratory signal, and movement signal. Since signals are measurements taken during the time, the problem is seen as time-series data classification. Deep learning methods are chosen to solve the problem are convolutional neural network and long-short term memory network. Input data is structured as a time-series sequence of mentioned signals that represent 30 seconds epoch, which is a standard interval for sleep analysis. The records used belong to the overall 23 subjects, which are divided into two subsets. Records from 18 subjects were used for training the data and from 5 subjects for testing the data. For detecting four sleep stages: REM (Rapid Eye Movement), Wake, Light sleep (Stage 1 and Stage 2), and Deep sleep (Stage 3 and Stage 4), the accuracy of the model is 55%, and F1 score is 44%. For five stages: REM, Stage 1, Stage 2, Deep sleep (Stage 3 and 4), and Wake, the model gives an accuracy of 40% and F1 score of 37%.
This work is a study about a comparison of survey tools and it should help developers in selecting a suited tool for application in an AAL environment. The first step was to identify the basic required functionality of the survey tools used for AAL technologies and to compare these tools by their functionality and assignments. The comparative study was derived from the data obtained, previous literature studies and further technical data. A list of requirements was stated and ordered in terms of relevance to the target application domain. With the help of an integrated assessment method, the calculation of a generalized estimate value was performed and the result is explained. Finally, the planned application of this tool in a running project is explained.
Cardiovascular diseases are directly or indirectly responsible for up to 38.5% of all deaths in Germany and thus represent the most frequent cause of death. At present, heart diseases are mainly discovered by chance during routine visits to the doctor or when acute symptoms occur. However, there is no practical method to proactively detect diseases or abnormalities of the heart in the daily environment and to take preventive measures for the person concerned. Long-term ECG devices, as currently used by physicians, are simply too expensive, impractical, and not widely available for everyday use. This work aims to develop an ECG device suitable for everyday use that can be worn directly on the body. For this purpose, an already existing hardware platform will be analyzed, and the corresponding potential for improvement will be identified. A precise picture of the existing data quality is obtained by metrological examination, and corresponding requirements are defined. Based on these identified optimization potentials, a new ECG device is developed. The revised ECG device is characterized by a high integration density and combines all components directly on one board except the battery and the ECG electrodes. The compact design allows the device to be attached directly to the chest. An integrated microcontroller allows digital signal processing without the need for an additional computer. Central features of the evaluation are a peak detection for detecting R-peaks and a calculation of the current heart rate based on the RR interval. To ensure the validity of the detected R-peaks, a model of the anatomical conditions is used. Thus, unrealistic RR-intervals can be excluded. The wireless interface allows continuous transmission of the calculated heart rate. Following the development of hardware and software, the results are verified, and appropriate conclusions about the data quality are drawn. As a result, a very compact and wearable ECG device with different wireless technologies, data storage, and evaluation of RR intervals was developed. Some tests yelled runtimes up to 24 hours with wireless Lan activated and streaming.
We present source code patterns that are difficult for modern static code analysis tools. Our study comprises 50 different open source projects in both a vulnerable and a fixed version for XSS vulnerabilities reported with CVE IDs over a period of seven years. We used three commercial and two open source static code analysis tools. Based on the reported vulnerabilities we discovered code patterns that appear to be difficult to classify by static analysis. The results show that code analysis tools are helpful, but still have problems with specific source code patterns. These patterns should be a focus in training for developers.
We propose and apply a requirements engineering approach that focuses on security and privacy properties and takes into account various stakeholder interests. The proposed methodology facilitates the integration of security and privacy by design into the requirements engineering process. Thus, specific, detailed security and privacy requirements can be implemented from the very beginning of a software project. The method is applied to an exemplary application scenario in the logistics industry. The approach includes the application of threat and risk rating methodologies, a technique to derive technical requirements from legal texts, as well as a matching process to avoid duplication and accumulate all essential requirements.
A residual neural network was adapted and applied to the Physionet/Computing data in Cardiology Challenge 2020 to detect 24 different classes of cardiac abnormalities from 12-lead. Additive Gaussian noise, signal shifting, and the classification of signal sections of different lengths were applied to prevent the network from overfitting and facilitating generalization. Due to the use of a global pooling layer after the feature extractor, the network is independent of the signal’s length. On the hidden test set of the challenge, the model achieved a validation score of 0.656 and a full test score of 0.27, placing us 15th out of 41 officially ranked teams (Team name: UC_Lab_Kn). These results show the potential of deep neural networks for ap- plication to raw data and a complex multi-class multi-label classification problem, even if the training data is from di- verse datasets and of differing lengths.
Methods based exclusively on heart rate hardly allow to differentiate between physical activity, stress, relaxation, and rest, that is why an additional sensor like activity/movement sensor added for detection and classification. The response of the heart to physical activity, stress, relaxation, and no activity can be very similar. In this study, we can observe the influence of induced stress and analyze which metrics could be considered for its detection. The changes in the Root Mean Square of the Successive Differences provide us with information about physiological changes. A set of measurements collecting the RR intervals was taken. The intervals are used as a parameter to distinguish four different stages. Parameters like skin conductivity or skin temperature were not used because the main aim is to maintain a minimum number of sensors and devices and thereby to increase the wearability in the future.
The ballistocardiography is a technique that measures the heart rate from the mechanical vibrations of the body due to the heart movement. In this work a novel noninvasive device placed under the mattress of a bed estimates the heart rate using the ballistocardiography. Different algorithms for heart rate estimation have been developed.
This document presents a new complete standalone system for a recognition of sleep apnea using signals from the pressure sensors placed under the mattress. The developed hardware part of the system is tuned to filter and to amplify the signal. Its software part performs more accurate signal filtering and identification of apnea events. The overall achieved accuracy of the recognition of apnea occurrence is 91%, with the average measured recognition delay of about 15 seconds, which confirms the suitability of the proposed method for future employment. The main aim of the presented approach is the support of the healthcare system with the cost-efficient tool for recognition of sleep apnea in the home environment.
Globalization has increased the number of road trips and vehicles. The result has been an intensification of traffic accidents, which are becoming one of the most important causes of death worldwide. Traffic accidents are often due to human error, the probability of which increases when the cognitive ability of the driver decreases. Cognitive capacity is closely related to the driver’s mental state, as well as other external factors such as the CO2 concentration inside the vehicle. The objective of this work is to analyze how these elements affect driving. We have conducted an experiment with 50 drivers who have driven for 25 min using a driving simulator. These drivers completed a survey at the start and end of the experiment to obtain information about their mental state. In addition, during the test, their stress level was monitored using biometric sensors and the state of the environment (temperature, humidity and CO2 level) was recorded. The results of the experiment show that the initial level of stress and tiredness of the driver can have a strong impact on stress, driving behavior and fatigue produced by the driving test. Other elements such as sadness and the conditions of the interior of the vehicle also cause impaired driving and affect compliance with traffic regulations.
In previous studies, we used a method for detecting stress that was based exclusively on heart rate and ECG for differentiation between such situations as mental stress, physical activity, relaxation, and rest. As a response of the heart to these situations, we observed different behavior in the Root Mean Square of the Successive differences heartbeats (RMSSD). This study aims to analyze Virtual Reality via a virtual reality headset as an effective stressor for future works. The value of the Root Mean Square of the Successive Differences is an important marker for the parasympathetic effector on the heart and can provide information about stress. For these measurements, the RR interval was collected using a breast belt. In these studies, we can observe the Root Mean Square of the successive differences heartbeats. Additional sensors for the analysis were not used. We conducted experiments with ten subjects that had to drive a simulator for 25 minutes using monitors and 25 minutes using virtual reality headset. Before starting and after finishing each simulation, the subjects had to complete a survey in which they had to describe their mental state. The experiment results show that driving using virtual reality headset has some influence on the heart rate and RMSSD, but it does not significantly increase the stress of driving.
Ballistocardiography (BCG) can be used to monitor heart rate activity. Besides, the accelerometer should have high sensitivity and minimal internal noise; a low-cost approach was taken into consideration. Several measurements have been executed to determine the optimal positioning of a sensor under the mattress to obtain a signal strong enough for further analysis. A prototype for an unobtrusive accelerometer-based measurement system has been developed and tested in a conventional bed without any specific extras. The influence of the human sleep position for the output accelerometer data was tested. The obtained results indicate the potential to capture BCG signals using accelerometers. The measurement system can detect heart rate in an unobtrusive form in the home environment.