Refine
Year of publication
Document Type
- Conference Proceeding (56)
- Article (13)
- Other Publications (1)
Keywords
- AAL (3)
- Accelerometer (3)
- Accelerometer sensor (1)
- Accelerometers (2)
- Accessibility (1)
- Ambient assisted living (2)
- Apnoe (1)
- Assisted living (1)
- Assistive systems (1)
- Atmung (2)
Institute
Long-term sleep monitoring can be done primarily in the home environment. Good patient acceptance requires low user and installation barriers. The selection of parameters in this approach is significantly limited compared to a PSG session. The aim is a qualified selection of parameters, which on the one hand allow a sufficiently good classification of sleep phases and on the other hand can be detected by non-invasive methods.
The process of restoring our body and brain from fatigue is directly depend-ing on the quality of sleep. It can be determined from the report of the sleep study results. Classification of sleep stages is the first step of this study and this includes the measurement of biovital data and its further processing.
In this work, the sleep analysis system is based on a hardware sensor net, namely a grid of 24 pressure sensors, supporting sleep phase recognition. In comparison to the leading standard, which is polysomnography, the proposed approach is a non-invasive system. It recognises respiration and body move-ment with only one type of low-cost pressure sensors forming a mesh archi-tecture. The nodes implement as a series of pressure sensors connected to a low-power and performant microcontroller. All nodes are connected via a system wide bus with address arbitration. The embedded processor is the mesh network endpoint that enables network configuration, storing and pre-processing of the data, external data access and visualization.
The system was tested by executing experiments recording the sleep of different healthy young subjects. The results obtained have indicated the po-tential to detect breathing rate and body movement. A major difference of this system in comparison to other approaches is the innovative way to place the sensors under the mattress. This characteristic facilitates the continuous using of the system without any influence on the common sleep process.
Objective: This paper presents an algorithm for non-invasive sleep stage identification using respiratory, heart rate and movement signals. The algorithm is part of a system suitable for long-term monitoring in a home environment, which should support experts analysing sleep. Approach: As there is a strong correlation between bio-vital signals and sleep stages, multinomial logistic regression was chosen for categorical distribution of sleep stages. Several derived parameters of three signals (respiratory, heart rate and movement) are input for the proposed method. Sleep recordings of five subjects were used for the training of a machine learning model and 30 overnight recordings collected from 30 individuals with about 27 000 epochs of 30 s intervals each were evaluated. Main results: The achieved rate of accuracy is 72% for Wake, NREM, REM (with Cohen's kappa value 0.67) and 58% for Wake, Light (N1 and N2), Deep (N3) and REM stages (Cohen's kappa is 0.50). Our approach has confirmed the potential of this method and disclosed several ways for its improvement. Significance: The results indicate that respiratory, heart rate and movement signals can be used for sleep studies with a reasonable level of accuracy. These inputs can be obtained in a non-invasive way applying it in a home environment. The proposed system introduces a convenient approach for a long-term monitoring system which could support sleep laboratories. The algorithm which was developed allows for an easy adjustment of input parameters that depend on available signals and for this reason could also be used with various hardware systems.
This document presents an algorithm for a non-obtrusive recognition of Sleep/Wake states using signals derived from ECG, respiration, and body movement captured while lying in a bed. As a core mathematical base of system data analytics, multinomial logistic regression techniques were chosen. Derived parameters of the three signals are used as the input for the proposed method. The overall achieved accuracy rate is 84% for Wake/Sleep stages, with Cohen’s kappa value 0.46. The presented algorithm should support experts in analyzing sleep quality in more detail. The results confirm the potential of this method and disclose several ways for its improvement.
Assistive environments are entering our homes faster than ever. However, there are still various barriers to be broken. One of the crucial points is a personalization of offered services and integration of assistive technologies in common objects and therefore in a regular daily routine. Recognition of sleep patterns for the preliminary sleep study is one of the health services that could be performed in an undisturbing way. This article proposes the hardware system for the measurement of bio-vital signals necessary for initial sleep study in a non-obtrusive way. The first results confirm the potential of measurement of breathing and movement signals with the proposed system.
The exposure to the light has a great influence on human beings in their everyday life. Various lighting sources produce light that reaches the human eye and influences a rhythmic release of melatonin hormone, that is a sleep promoting factor.
Since the development of new technologies provides more control over illuminance, this work uses an IoT based lighting system to set up dim and bright scenarios. A small study has been performed on the influence of illuminance on sleep latency. The system consists of different light bulbs, sensors and a central bridge which are interconnected like a mesh network. Also, a mobile app has been developed, that allows to adjust the lighting in various rooms. With the help of a ferro-electret sensor, like applied in sleep monitoring systems, a subject’s sleep was monitored. The sensor is placed below the mattress and it collects data, which is stored and processed in a cloud or in other alternative locations.
The research was conducted on healthy young subjects after being previously exposed to the preconfigured illuminance for at least three hours before bedtime. The results indicate correlation between sleep onset latency and exposure to different illuminance before bedtime. In a dimmed environment, the subject fell asleep in average 28% faster compared to the brighter environment.
The goal of this paper pretends to show how a bed system with an embedded system with sensor is able to analyze a person’s movement, breathing and recognizing the positions that the subject is lying on the bed during the night without any additional physical contact. The measurements are performed with sensors placed between the mattress and the frame. An Intel Edison board was used as an endpoint that served as a communication node from the mesh network to external service. Two nodes and Intel Edison are attached to the bottom of the bed frame and they are connected to the sensors.