Refine
Year of publication
Document Type
- Conference Proceeding (72)
- Article (25)
- Part of a Book (1)
- Other Publications (1)
Keywords
- 1D-CNN (1)
- AAL (2)
- AHI (1)
- Accelerometer (3)
- Accelerometer sensor (2)
- Accelerometers (2)
- Accessibility (1)
- Activity monitoring (1)
- Algorithm (1)
- Ambient assisted living (1)
Institute
In previous studies, we used a method for detecting stress that was based exclusively on heart rate and ECG for differentiation between such situations as mental stress, physical activity, relaxation, and rest. As a response of the heart to these situations, we observed different behavior in the Root Mean Square of the Successive differences heartbeats (RMSSD). This study aims to analyze Virtual Reality via a virtual reality headset as an effective stressor for future works. The value of the Root Mean Square of the Successive Differences is an important marker for the parasympathetic effector on the heart and can provide information about stress. For these measurements, the RR interval was collected using a breast belt. In these studies, we can observe the Root Mean Square of the successive differences heartbeats. Additional sensors for the analysis were not used. We conducted experiments with ten subjects that had to drive a simulator for 25 minutes using monitors and 25 minutes using virtual reality headset. Before starting and after finishing each simulation, the subjects had to complete a survey in which they had to describe their mental state. The experiment results show that driving using virtual reality headset has some influence on the heart rate and RMSSD, but it does not significantly increase the stress of driving.
The citizen-centered health platform project is intended to provide a platform that can be used in EU cross-border regions, where social and economic exchange occurs across national borders. The overriding challenges are: (a) social: improving citizen-centered health and care provision; (b) technical: providing a digital platform for networking citizens, service providers, and municipal actors; (c) economic: developing long-term successful (sustainable) business models/value chains. The platform should strengthen and expand existing networks and establish new regional networks. Each network addresses particular challenges and apply them in a region-specific manner. Here, the national boundary conditions and the interregional needs play an essential role. These objectives require sufficient participation of civil society representatives. Furthermore, the platform will establish an overarching, sustainable, and knowledge-based network of health experts. The platform is to be jointly developed and implemented in the regions and follow an open-access approach. Therefore, synergies will be shared more quickly, strengthening competencies and competitiveness. In addition to practice partners, scientific and municipal institutions and SMEs are involved. The actors thus contribute to scientific performance, innovative strength, and resilience.
Cardiovascular diseases (CVD) are leading contributors to global mortality, necessitating advanced methods for vital sign monitoring. Heart Rate Variability (HRV) and Respiratory Rate, key indicators of cardiovascular health, are traditionally monitored via Electrocardiogram (ECG). However, ECG's obtrusiveness limits its practicality, prompting the exploration of Ballistocardiography (BCG) as a non-invasive alternative. BCG records the mechanical activity of the body with each heartbeat, offering a contactless method for HRV monitoring. Despite its benefits, BCG signals are susceptible to external interference and present a challenge in accurately detecting J-Peaks. This research uses advanced signal processing and deep learning techniques to overcome these limitations. Our approach integrates accelerometers for long-term BCG data collection during sleep, applying Discrete Wavelet Transforms (DWT) and Ensemble Empirical Mode Decomposition (EEMD) for feature extraction. The Bi-LSTM model, leveraging these features, enhances heartbeat detection, offering improved reliability over traditional methods. The study's findings indicate that the combined use of DWT, EEMD, and Bi-LSTM for J-Peak detection in BCG signals is effective, with potential applications in unobtrusive long-term cardiovascular monitoring. Our results suggest that this methodology could contribute to HRV monitoring, particularly in home settings, enhancing patient comfort and compliance.
Good sleep is crucial for a healthy life of every person. Unfortunately, its quality often decreases with aging. A common approach to measuring the sleep characteristics is based on interviews with the subjects or letting them fill in a daily questionnaire and afterward evaluating the obtained data. However, this method has time and personal costs for the interviewer and evaluator of responses. Therefore, it would be important to execute the collection and evaluation of sleep characteristics automatically. To do that, it is necessary to investigate the level of agreement between measurements performed in a traditional way using questionnaires and measurements obtained using electronic monitoring devices. The study presented in this manuscript performs this investigation, comparing such sleep characteristics as "time going to bed", "total time in bed", "total sleep time" and "sleep efficiency". A total number of 106 night records of elderly persons (aged 65+) were analyzed. The results achieved so far reveal the fact that the degree of agreement between the two measurement methods varies substantially for different characteristics, from 31 minutes of mean difference for "time going to bed" to 77 minutes for "total sleep time". For this reason, a direct exchange of objective and subjective measuring methods is currently not possible.
Healthy sleep is one of the prerequisites for a good human body and brain condition, including general well-being. Unfortunately, there are several sleep disorders that can negatively affect this. One of the most common is sleep apnoea, in which breathing is impaired. Studies have shown that this disorder often remains undiagnosed. To avoid this, developing a system that can be widely used in a home environment to detect apnoea and monitor the changes once therapy has been initiated is essential. The conceptualisation of such a system is the main aim of this research. After a thorough analysis of the available literature and state of the art in this area of knowledge, a concept of the system was created, which includes the following main components: data acquisition (including two parts), storage of the data, apnoea detection algorithm, user and device management, data visualisation. The modules are interchangeable, and interfaces have been defined for data transfer, most of which operate using the MQTT protocol. System diagrams and detailed component descriptions, including signal requirements and visualisation mockups, have also been developed. The system's design includes the necessary concepts for the implementation and can be realised in a prototype in the next phase.
Long-term sleep monitoring can be done primarily in the home environment. Good patient acceptance requires low user and installation barriers. The selection of parameters in this approach is significantly limited compared to a PSG session. The aim is a qualified selection of parameters, which on the one hand allow a sufficiently good classification of sleep phases and on the other hand can be detected by non-invasive methods.
Sleep is essential to physical and mental health. However, the traditional approach to sleep analysis—polysomnography (PSG)—is intrusive and expensive. Therefore, there is great interest in the development of non-contact, non-invasive, and non-intrusive sleep monitoring systems and technologies that can reliably and accurately measure cardiorespiratory parameters with minimal impact on the patient. This has led to the development of other relevant approaches, which are characterised, for example, by the fact that they allow greater freedom of movement and do not require direct contact with the body, i.e., they are non-contact. This systematic review discusses the relevant methods and technologies for non-contact monitoring of cardiorespiratory activity during sleep. Taking into account the current state of the art in non-intrusive technologies, we can identify the methods of non-intrusive monitoring of cardiac and respiratory activity, the technologies and types of sensors used, and the possible physiological parameters available for analysis. To do this, we conducted a literature review and summarised current research on the use of non-contact technologies for non-intrusive monitoring of cardiac and respiratory activity. The inclusion and exclusion criteria for the selection of publications were established prior to the start of the search. Publications were assessed using one main question and several specific questions. We obtained 3774 unique articles from four literature databases (Web of Science, IEEE Xplore, PubMed, and Scopus) and checked them for relevance, resulting in 54 articles that were analysed in a structured way using terminology. The result was 15 different types of sensors and devices (e.g., radar, temperature sensors, motion sensors, cameras) that can be installed in hospital wards and departments or in the environment. The ability to detect heart rate, respiratory rate, and sleep disorders such as apnoea was among the characteristics examined to investigate the overall effectiveness of the systems and technologies considered for cardiorespiratory monitoring. In addition, the advantages and disadvantages of the considered systems and technologies were identified by answering the identified research questions. The results obtained allow us to determine the current trends and the vector of development of medical technologies in sleep medicine for future researchers and research.
The actual task of electrocardiographic examinations is to increase the reliability of diagnosing the condition of the heart. Within the framework of this task, an important direction is the solution of the inverse problem of electrocardiography, based on the processing of electrocardiographic signals of multichannel cardio leads at known electrode coordinates in these leads (Titomir et al. Noninvasiv electrocardiotopography, 2003), (Macfarlane et al. Comprehensive Electrocardiology, 2nd ed. (Chapter 9), 2011).
The scoring of sleep stages is one of the essential tasks in sleep analysis. Since a manual procedure requires considerable human and financial resources, and incorporates some subjectivity, an automated approach could result in several advantages. There have been many developments in this area, and in order to provide a comprehensive overview, it is essential to review relevant recent works and summarise the characteristics of the approaches, which is the main aim of this article. To achieve it, we examined articles published between 2018 and 2022 that dealt with the automated scoring of sleep stages. In the final selection for in-depth analysis, 125 articles were included after reviewing a total of 515 publications. The results revealed that automatic scoring demonstrates good quality (with Cohen's kappa up to over 0.80 and accuracy up to over 90%) in analysing EEG/EEG + EOG + EMG signals. At the same time, it should be noted that there has been no breakthrough in the quality of results using these signals in recent years. Systems involving other signals that could potentially be acquired more conveniently for the user (e.g. respiratory, cardiac or movement signals) remain more challenging in the implementation with a high level of reliability but have considerable innovation capability. In general, automatic sleep stage scoring has excellent potential to assist medical professionals while providing an objective assessment.