Institute
The goal of this paper pretends to show how a bed system with an embedded system with sensor is able to analyze a person’s movement, breathing and recognizing the positions that the subject is lying on the bed during the night without any additional physical contact. The measurements are performed with sensors placed between the mattress and the frame. An Intel Edison board was used as an endpoint that served as a communication node from the mesh network to external service. Two nodes and Intel Edison are attached to the bottom of the bed frame and they are connected to the sensors.
This paper presents a generic method to enhance performance and incorporate temporal information for cardiorespiratory-based sleep stage classification with a limited feature set and limited data. The classification algorithm relies on random forests and a feature set extracted from long-time home monitoring for sleep analysis. Employing temporal feature stacking, the system could be significantly improved in terms of Cohen’s κ and accuracy. The detection performance could be improved for three classes of sleep stages (Wake, REM, Non-REM sleep), four classes (Wake, Non-REM-Light sleep, Non-REM Deep sleep, REM sleep), and five classes (Wake, N1, N2, N3/4, REM sleep) from a κ of 0.44 to 0.58, 0.33 to 0.51, and 0.28 to 0.44 respectively by stacking features before and after the epoch to be classified. Further analysis was done for the optimal length and combination method for this stacking approach. Overall, three methods and a variable duration between 30 s and 30 min have been analyzed. Overnight recordings of 36 healthy subjects from the Interdisciplinary Center for Sleep Medicine at Charité-Universitätsmedizin Berlin and Leave-One-Out-Cross-Validation on a patient-level have been used to validate the method.
The scoring of sleep stages is an essential part of sleep studies. The main objective of this research is to provide an algorithm for the automatic classification of sleep stages using signals that may be obtained in a non-obtrusive way. After reviewing the relevant research, the authors selected a multinomial logistic regression as the basis for their approach. Several parameters were derived from movement and breathing signals, and their combinations were investigated to develop an accurate and stable algorithm. The algorithm was implemented to produce successful results: the accuracy of the recognition of Wake/NREM/REM stages is equal to 73%, with Cohen's kappa of 0.44 for the analyzed 19324 sleep epochs of 30 seconds each. This approach has the advantage of using the only movement and breathing signals, which can be recorded with less effort than heart or brainwave signals, and requiring only four derived parameters for the calculations. Therefore, the new system is a significant improvement for non-obtrusive sleep stage identification compared to existing approaches.
The purpose of this paper is to examine the effects of perceived stress on traffic and road safety. One of the leading causes of stress among drivers is the feeling of having a lack of control during the driving process. Stress can result in more traffic accidents, an increase in driver errors, and an increase in traffic violations. To study this phenomenon, the Stress Perceived Questionnaire (PSQ) was used to evaluate the perceived stress while driving in a simulation. The study was conducted with participants from Germany, and they were grouped into different categories based on their emotional stability. Each participant was monitored using wearable devices that measured their instantaneous heart rate (HR). The preference for wearable devices was due to their non-intrusive and portable nature. The results of this study provide an overview of how stress can affect traffic and road safety, which can be used for future research or to implement strategies to reduce road accidents and promote traffic safety.
Recognition of sleep and wake states is one of the relevant parts of sleep analysis. Performing this measurement in a contactless way increases comfort for the users. We present an approach evaluating only movement and respiratory signals to achieve recognition, which can be measured non-obtrusively. The algorithm is based on multinomial logistic regression and analyses features extracted out of mentioned above signals. These features were identified and developed after performing fundamental research on characteristics of vital signals during sleep. The achieved accuracy of 87% with the Cohen’s kappa of 0.40 demonstrates the appropriateness of a chosen method and encourages continuing research on this topic.
Evaluation of a Contactless Accelerometer Sensor System for Heart Rate Monitoring During Sleep
(2024)
The monitoring of a patient's heart rate (HR) is critical in the diagnosis of diseases. In the detection of sleep disorders, it also plays an important role. Several techniques have been proposed, including using sensors to record physiological signals that are automatically examined and analysed. This work aims to evaluate using a contactless HR monitoring system based on an accelerometer sensor during sleep. For this purpose, the oscillations caused by chest movements during heart contractions are recorded by an installation mounted under the bed mattress. The processing algorithm presented in this paper filters the signals and determines the HR. As a result, an average error of about 5 bpm has been documented, i.e., the system can be considered to be used for the forecasted domain.
Nowadays, the importance of early active patient mobilization in the recovery and rehabilitation phase has increased significantly. One way to involve patients in the treatment is a gamification-like approach, which is one of the methods of motivation in various life processes. This article shows a system prototype for patients who require physical activity because of active early mobilization after medical interventions or during illness. Bedridden patients and people with a sedentary lifestyle (predominantly lying in bed) are also potential users. The main idea for the concept was non-contact system implementation for the patients making them feel effortless during its usage. The system consists of three related parts: hardware, software, and game application. To test the relevance and coherence of the system, it was used by 35 people. The participants were asked to play a video game requiring them to make body movements while lying down. Then they were asked to take part in a small survey to evaluate the system's usability. As a result, we offer a prototype consisting of hardware and software parts that can increase and diversify physical activity during active early mobilization of patients and prevent the occurrence of possible health problems due to predominantly low activity. The proposed design can be possibly implemented in hospitals, rehabilitation centers, and even at home.
The importance of sleep for human life is enormous. It affects physical, mental, and psychological health. Therefore, it is vital to recognise sleep disorders in a timely manner in order to be able to initiate therapy. There are two methods for measuring sleep-related parameters - objective and subjective. Whether the substitution of a subjective method for an objective one is possible is investigated in this paper. Such replacement may bring several advantages, including increased comfort for the user. To answer this research question, a study was conducted in which 75 overnight recordings were evaluated. The primary purpose of this study was to compare both ways of measurement for total sleep time and sleep efficiency, which are essential parameters for, e.g., insomnia diagnosis and treatment. The evaluation results demonstrated that, on average, there are 32 minutes of difference between the two measurement methods when total sleep time is analysed. In contrast, on average, both measurement methods differ by 7.5% for sleep efficiency measurement. It should also be noted that people typically overestimate total sleep time and efficiency with the subjective method, where the perceived values are measured.
The principal objective of this study is to investigate the impact of perceived stress on traffic and road safety. Therefore, we designed a study that allows the generation and collection of stress-relevant data. Drivers often experience stress due to their perception of lack of control during the driving process. This can lead to an increased likelihood of traffic accidents, driver errors, and traffic violations. To explore this phenomenon, we used the Stress Perceived Questionnaire (PSQ) to evaluate perceived stress levels during driving simulations and the EPQR questionnaire to determine the personality of the driver. With the presented study, participants can categorised based on their emotional stability and personality traits. Wearable devices were utilised to monitor each participant's instantaneous heart rate (HR) due to their non-intrusive and portable nature. The findings of this study deliver an overview of the link between stress and traffic and road safety. These findings can be utilised for future research and implementing strategies to reduce road accidents and promote traffic safety.
Nowadays there is a rich diversity of sleep monitoring systems available on the market. They promise to offer information about sleep quality of the user by recording a limited number of vital signals, mainly heart rate and body movement. Typically, fitness trackers, smart watches, smart shirts, smartphone applications or patches do not provide access to the raw sensor data. Moreover, the sleep classification algorithm and the agreement ratio with the gold standard, polysomnography (PSG) are not disclosed. Some commercial systems record and store the data on the wearable device, but the user needs to transfer and import it into specialised software applications or return it to the doctor, for clinical evaluation of the data set. Thus an immediate feedback mechanism or the possibility of remote control and supervision are lacking. Furthermore, many such systems only distinguish between sleep and wake states, or between wake, light sleep and deep sleep. It is not always clear how these stages are mapped to the four known sleep stages: REM, NREM1, NREM2, NREM3-4. [1] The goal of this research is to find a reduced complexity method to process a minimum number of bio vital signals, while providing accurate sleep classification results. The model we propose offers remote control and real time supervision capabilities, by using Internet of Things (IoT) technology. This paper focuses on the data processing method and the sleep classification logic. The body sensor network representing our data acquisition system will be described in a separate publication. Our solution showed promising results and a good potential to overcome the limitations of existing products. Further improvements will be made and subjects with different age and health conditions will be tested.