Refine
Year of publication
- 2020 (17) (remove)
Document Type
- Conference Proceeding (15)
- Article (2)
Keywords
- Accelerometers (1)
- Apnoe (1)
- Assisted living (1)
- BCG (1)
- Ballistokardiographie (1)
- Biosignal analysis (1)
- Biosignal processing (1)
- Biovital signal (2)
- Breathing (1)
- Breathing rate (1)
Institute
This paper presents the implementation of deep learning methods for sleep stage detection by using three signals that can be measured in a non-invasive way: heartbeat signal, respiratory signal, and movement signal. Since signals are measurements taken during the time, the problem is seen as time-series data classification. Deep learning methods are chosen to solve the problem are convolutional neural network and long-short term memory network. Input data is structured as a time-series sequence of mentioned signals that represent 30 seconds epoch, which is a standard interval for sleep analysis. The records used belong to the overall 23 subjects, which are divided into two subsets. Records from 18 subjects were used for training the data and from 5 subjects for testing the data. For detecting four sleep stages: REM (Rapid Eye Movement), Wake, Light sleep (Stage 1 and Stage 2), and Deep sleep (Stage 3 and Stage 4), the accuracy of the model is 55%, and F1 score is 44%. For five stages: REM, Stage 1, Stage 2, Deep sleep (Stage 3 and 4), and Wake, the model gives an accuracy of 40% and F1 score of 37%.
Cardiovascular diseases are directly or indirectly responsible for up to 38.5% of all deaths in Germany and thus represent the most frequent cause of death. At present, heart diseases are mainly discovered by chance during routine visits to the doctor or when acute symptoms occur. However, there is no practical method to proactively detect diseases or abnormalities of the heart in the daily environment and to take preventive measures for the person concerned. Long-term ECG devices, as currently used by physicians, are simply too expensive, impractical, and not widely available for everyday use. This work aims to develop an ECG device suitable for everyday use that can be worn directly on the body. For this purpose, an already existing hardware platform will be analyzed, and the corresponding potential for improvement will be identified. A precise picture of the existing data quality is obtained by metrological examination, and corresponding requirements are defined. Based on these identified optimization potentials, a new ECG device is developed. The revised ECG device is characterized by a high integration density and combines all components directly on one board except the battery and the ECG electrodes. The compact design allows the device to be attached directly to the chest. An integrated microcontroller allows digital signal processing without the need for an additional computer. Central features of the evaluation are a peak detection for detecting R-peaks and a calculation of the current heart rate based on the RR interval. To ensure the validity of the detected R-peaks, a model of the anatomical conditions is used. Thus, unrealistic RR-intervals can be excluded. The wireless interface allows continuous transmission of the calculated heart rate. Following the development of hardware and software, the results are verified, and appropriate conclusions about the data quality are drawn. As a result, a very compact and wearable ECG device with different wireless technologies, data storage, and evaluation of RR intervals was developed. Some tests yelled runtimes up to 24 hours with wireless Lan activated and streaming.
This work is a study about a comparison of survey tools and it should help developers in selecting a suited tool for application in an AAL environment. The first step was to identify the basic required functionality of the survey tools used for AAL technologies and to compare these tools by their functionality and assignments. The comparative study was derived from the data obtained, previous literature studies and further technical data. A list of requirements was stated and ordered in terms of relevance to the target application domain. With the help of an integrated assessment method, the calculation of a generalized estimate value was performed and the result is explained. Finally, the planned application of this tool in a running project is explained.
In diesem Beitrag wird eine Methode des maschinellen Lernens entwickelt, die die Schlafstadienerkennung untersucht. Übliche Methoden der Schlafanalyse basieren auf der Polysomnographie (PSG). Der präsentierte Ansatz basiert auf Signalen, die ausschließlich nicht-invasiv in einer häuslichen Umgebung gemessen werden können. Bewegungs-, Herzschlags- und Atmungssignale können vergleichsweise leicht erfasst werden aber die Erkennung der Schlafstadien ist dadurch erschwert. Die Signale werden als Zeitreihenfolge strukturiert und in Epochen überführt. Die Leistungsfähigkeit von maschinellem Lernen wird der Polysomnographie gegenübergestellt und bewertet.
In previous studies, we used a method for detecting stress that was based exclusively on heart rate and ECG for differentiation between such situations as mental stress, physical activity, relaxation, and rest. As a response of the heart to these situations, we observed different behavior in the Root Mean Square of the Successive differences heartbeats (RMSSD). This study aims to analyze Virtual Reality via a virtual reality headset as an effective stressor for future works. The value of the Root Mean Square of the Successive Differences is an important marker for the parasympathetic effector on the heart and can provide information about stress. For these measurements, the RR interval was collected using a breast belt. In these studies, we can observe the Root Mean Square of the successive differences heartbeats. Additional sensors for the analysis were not used. We conducted experiments with ten subjects that had to drive a simulator for 25 minutes using monitors and 25 minutes using virtual reality headset. Before starting and after finishing each simulation, the subjects had to complete a survey in which they had to describe their mental state. The experiment results show that driving using virtual reality headset has some influence on the heart rate and RMSSD, but it does not significantly increase the stress of driving.
A residual neural network was adapted and applied to the Physionet/Computing data in Cardiology Challenge 2020 to detect 24 different classes of cardiac abnormalities from 12-lead. Additive Gaussian noise, signal shifting, and the classification of signal sections of different lengths were applied to prevent the network from overfitting and facilitating generalization. Due to the use of a global pooling layer after the feature extractor, the network is independent of the signal’s length. On the hidden test set of the challenge, the model achieved a validation score of 0.656 and a full test score of 0.27, placing us 15th out of 41 officially ranked teams (Team name: UC_Lab_Kn). These results show the potential of deep neural networks for ap- plication to raw data and a complex multi-class multi-label classification problem, even if the training data is from di- verse datasets and of differing lengths.
Good sleep is crucial for a healthy life of every person. Unfortunately, its quality often decreases with aging. A common approach to measuring the sleep characteristics is based on interviews with the subjects or letting them fill in a daily questionnaire and afterward evaluating the obtained data. However, this method has time and personal costs for the interviewer and evaluator of responses. Therefore, it would be important to execute the collection and evaluation of sleep characteristics automatically. To do that, it is necessary to investigate the level of agreement between measurements performed in a traditional way using questionnaires and measurements obtained using electronic monitoring devices. The study presented in this manuscript performs this investigation, comparing such sleep characteristics as "time going to bed", "total time in bed", "total sleep time" and "sleep efficiency". A total number of 106 night records of elderly persons (aged 65+) were analyzed. The results achieved so far reveal the fact that the degree of agreement between the two measurement methods varies substantially for different characteristics, from 31 minutes of mean difference for "time going to bed" to 77 minutes for "total sleep time". For this reason, a direct exchange of objective and subjective measuring methods is currently not possible.
The actual task of electrocardiographic examinations is to increase the reliability of diagnosing the condition of the heart. Within the framework of this task, an important direction is the solution of the inverse problem of electrocardiography, based on the processing of electrocardiographic signals of multichannel cardio leads at known electrode coordinates in these leads (Titomir et al. Noninvasiv electrocardiotopography, 2003), (Macfarlane et al. Comprehensive Electrocardiology, 2nd ed. (Chapter 9), 2011).
Für die Überwachung des Schlafs zu Hause sind nichtinvasive Methoden besonders gut anwendbar. Die Signale, die häufig überwacht werden, sind Herzfrequenz und Atemfrequenz. Die Ballistokardiographie (BCG)ist eine Technik, bei der die Herzfrequenz aus den mechanischen Schwingungen des Körpers bei jedem Herzzyklus gemessen wird. Kürzlich wurden Übersichtsarbeiten veröffentlicht. Die Untersuchung soll in einem ersten Ansatz bewerten, ob die Herzfrequenz anhand von BCG erkannt werden kann. Die wesentlichen Randbedingungen sind, ob dies gelingt, wenn der Sensor unter der Matratze positioniert wird und kostengünstige Sensoren zum Einsatz kommen.
This document presents a new complete standalone system for a recognition of sleep apnea using signals from the pressure sensors placed under the mattress. The developed hardware part of the system is tuned to filter and to amplify the signal. Its software part performs more accurate signal filtering and identification of apnea events. The overall achieved accuracy of the recognition of apnea occurrence is 91%, with the average measured recognition delay of about 15 seconds, which confirms the suitability of the proposed method for future employment. The main aim of the presented approach is the support of the healthcare system with the cost-efficient tool for recognition of sleep apnea in the home environment.