The actual task of electrocardiographic examinations is to increase the reliability of diagnosing the condition of the heart. Within the framework of this task, an important direction is the solution of the inverse problem of electrocardiography, based on the processing of electrocardiographic signals of multichannel cardio leads at known electrode coordinates in these leads (Titomir et al. Noninvasiv electrocardiotopography, 2003), (Macfarlane et al. Comprehensive Electrocardiology, 2nd ed. (Chapter 9), 2011).
Healthy and good sleep is a prerequisite for a rested mind and body. Both form the basis for physical and mental health. Healthy sleep is hindered by sleep disorders, the medically diagnosed frequency of which increases sharply from the age of 40. This chapter describes the formal specification of an on-course practical implementation for a non-invasive system based on biomedical signal processing to support the diagnosis and treatment of sleep-related diseases. The system aims to continuously monitor vital data during sleep in a patient’s home environment over long periods by using non-invasive technologies. At the center of the development is the MORPHEUS Box (MoBo), which consists of five main conceptualizations: the MoBo core, the MoBo-HW, the MoBo algorithm, the MoBo API, and the MoBo app. These synergistic elements aim to support the diagnosis and treatment of sleep-related diseases. Although there are related developments in individual aspects concerning the system, no comparative approach is known that gives a similar scope of functionality, deployment flexibility, extensibility, or the possibility to use multiple user groups. With the specification provided in this chapter, the MORPHEUS project sets a good platform, data model, and transmission strategies to bring an innovative proposal to measure sleep quality and detect sleep diseases from non-invasive sensors.
This paper compares two popular scripting implementations for hardware prototyping: Python scripts exe- cut from User-Space and C-based Linux-Driver processes executed from Kernel-Space, which can provide information to researchers when considering one or another in their implementations. Conclusions exhibit that deploying software scripts in the kernel space makes it possible to grant a certain quality of sensor information using a Raspberry Pi without the need for advanced real-time operational systems.
Background: Polysomnography (PSG) is the gold standard for detecting obstructive sleep apnea (OSA). However, this technique has many disadvantages when using it outside the hospital or for daily use. Portable monitors (PMs) aim to streamline the OSA detection process through deep learning (DL).
Materials and methods: We studied how to detect OSA events and calculate the apnea-hypopnea index (AHI) by using deep learning models that aim to be implemented on PMs. Several deep learning models are presented after being trained on polysomnography data from the National Sleep Research Resource (NSRR) repository. The best hyperparameters for the DL architecture are presented. In addition, emphasis is focused on model explainability techniques, concretely on Gradient-weighted Class Activation Mapping (Grad-CAM).
Results: The results for the best DL model are presented and analyzed. The interpretability of the DL model is also analyzed by studying the regions of the signals that are most relevant for the model to make the decision. The model that yields the best result is a one-dimensional convolutional neural network (1D-CNN) with 84.3% accuracy.
Conclusion: The use of PMs using machine learning techniques for detecting OSA events still has a long way to go. However, our method for developing explainable DL models demonstrates that PMs appear to be a promising alternative to PSG in the future for the detection of obstructive apnea events and the automatic calculation of AHI.
Introduction. Despite its high accuracy, polysomnography (PSG) has several drawbacks for diagnosing obstructive sleep apnea (OSA). Consequently, multiple portable monitors (PMs) have been proposed. Objective. This systematic review aims to investigate the current literature to analyze the sets of physiological parameters captured by a PM to select the minimum number of such physiological signals while maintaining accurate results in OSA detection. Methods. Inclusion and exclusion criteria for the selection of publications were established prior to the search. The evaluation of the publications was made based on one central question and several specific questions. Results. The abilities to detect hypopneas, sleep time, or awakenings were some of the features studied to investigate the full functionality of the PMs to select the most relevant set of physiological signals. Based on the physiological parameters collected (one to six), the PMs were classified into sets according to the level of evidence. The advantages and the disadvantages of each possible set of signals were explained by answering the research questions proposed in the methods. Conclusions. The minimum number of physiological signals detected by PMs for the detection of OSA depends mainly on the purpose and context of the sleep study. The set of three physiological signals showed the best results in the detection of OSA.
The massive use of patient data for the training of artificial intelligence algorithms is common nowadays in medicine. In this scientific work, a statistical analysis of one of the most used datasets for the training of artificial intelligence models for the detection of sleep disorders is performed: sleep health heart study 2. This study focuses on determining whether the gender and age of the patients have a relevant influence to consider working with differentiated datasets based on these variables for the training of artificial intelligence models.
While driving, stress is caused by situations in which the driver estimates their ability to manage the driving demands as insufficient or loses the capability to handle the situation. This leads to increased numbers of driver mistakes and traffic violations. Additional stressing factors are time pressure, road conditions, or dislike for driving. Therefore, stress affects driver and road safety. Stress is classified into two categories depending on its duration and the effects on the body and psyche: short-term eustress and constantly present distress, which causes degenerative effects. In this work, we focus on distress. Wearable sensors are handy tools for collecting biosignals like heart rate, activity, etc. Easy installation and non-intrusive nature make them convenient for calculating stress. This study focuses on the investigation of stress and its implications. Specifically, the research conducts an analysis of stress within a select group of individuals from both Spain and Germany. The primary objective is to examine the influence of recognized psychological factors, including personality traits such as neuroticism, extroversion, psychoticism, stress and road safety. The estimation of stress levels was accomplished through the collection of physiological parameters (R-R intervals) using a Polar H10 chest strap. We observed that personality traits, such as extroversion, exhibited similar trends during relaxation, with an average heart rate 6% higher in Spain and 3% higher in Germany. However, while driving, introverts, on average, experienced more stress, with rates 4% and 1% lower than extroverts in Spain and Germany, respectively.
The present work proposes the use of modern ICT technologies such as smartphones, NFCs, internet, and web technologies, to help patients in carrying out their therapies. The implemented system provides a calendar with a reminder of the assumptions, ensures the drug identification through NFC, allows remote assistance from healthcare staff and family members to check and manage the therapy in real-time. The system also provides centralized information on the patient's therapeutic situation, helpful in choosing new compatible therapies.
Unintrusive health monitoring systems is important when continuous monitoring of the patient vital signals is required. In this paper, signals obtained from accelerometers placed under a bed are processed with ballistocardiography algorithms and compared with synchronized electrocardiographic signals.
Apnea is a sleep disorder characterized by breathing interruptions during sleep, impacting cardiorespiratory function and overall health. Traditional diagnostic methods, like polysomnography (PSG), are unobtrusive, leading to noninvasive monitoring. This study aims to develop and validate a novel sleep monitoring system using noninvasive sensor technology to estimate cardiorespiratory parameters and detect sleep apnea. We designed a seamless monitoring system integrating noncontact force-sensitive resistor sensors to collect ballistocardiogram signals associated with cardiorespiratory activity. We enhanced the sensor’s sensitivity and reduced the noise by designing a new concept of edge-measuring sensor using a hemisphere dome and mechanical hanger to distribute the force and mechanically amplify the micromovement caused by cardiac and respiration activities. In total, we deployed three edge-measuring sensors, two deployed under the thoracic and one under the abdominal regions. The system is supported with onboard signal preprocessing in multiple physical layers deployed under the mattress. We collected the data in four sleeping positions from 16 subjects and analyzed them using ensemble empirical mode decomposition (EMD) to avoid frequency mixing. We also developed an adaptive thresholding method to identify sleep apnea. The error was reduced to 3.98 and 1.43 beats/min (BPM) in heart rate (HR) and respiration estimation, respectively. The apnea was detected with an accuracy of 87%. We optimized the system such that only one edge-measuring sensor can measure the cardiorespiratory parameters. Such a reduction in the complexity and simplification of the instruction of use shows excellent potential for in-home and continuous monitoring.