Refine
Year of publication
- 2019 (15) (remove)
Document Type
- Conference Proceeding (8)
- Article (3)
- Report (3)
- Other Publications (1)
Keywords
- AAL (2)
- Activity monitoring (1)
- Ambient assisted living (1)
- Artefaktkorrektur (1)
- Atmung (2)
- Automotive (1)
- Bewegung (1)
- Biomedical Signal Capturing (1)
- Drowsiness (1)
- E-Health (1)
Institute
- Fakultät Informatik (15) (remove)
The investigation of stress requires to distinguish between stress caused by physical activity and stress that is caused by psychosocial factors. The behaviour of the heart in response to stress and physical activity is very similar in case the set of monitored parameters is reduced to one. Currently, the differentiation remains difficult and methods which only use the heart rate are not able to differentiate between stress and physical activity, without using additional sensor data input. The approach focusses on methods which generate signals providing characteristics that are useful for detecting stress, physical activity, no activity and relaxation.
A significant proportion of road traffic accidents are due to inattentiveness or fatigue at the wheel. Approaches to monitoring the driver's condition range from eye tracking and driving behavior analysis to yawn and blink detection and ECG measurement. This work describes the development of a mobile system for the measurement and processing of ECG data. The aim of the signal processing is to quantify the driver’s fatigue with the heartrate variability (HRV). The work includes the hardware and software design of the sensor. First, the development of low-noise electronics including AD conversion is described. Then the software signal processing with QRS complex detection and plotting front end is explained. The resulting sensor is compact, low-cost and provides a good signal for HRV extraction.
Fatigue and drowsiness are responsible for a significant percentage of road traffic accidents. There are several approaches to monitor the driver’s drowsiness, ranging from the driver’s steering behavior to analysis of the driver, e.g. eye tracking, blinking, yawning or electrocardiogram (ECG). This paper describes the development of a low-cost ECG sensor to derive heart rate variability (HRV) data for the drowsiness detection. The work includes the hardware and the software design. The hardware has been implemented on a printed circuit board (PCB) designed so that the board can be used as an extension shield for an Arduino. The PCB contains a double, inverted ECG channel including low-pass filtering and provides two analog outputs to the Arduino, that combined them and performs the analog-to-digital conversion. The digital ECG signal is transferred to an NVidia embedded PC where the processing takes place, including QRS-complex, heart rate and HRV detection as well as visualization features. The compact resulting sensor provides good results in the extraction of the main ECG parameters. The sensor is being used in a larger frame, where facial-recognition-based drowsiness detection is combined with ECG-based detection to improve the recognition rate under unfavorable light or occlusion conditions.
The goal of the presented project is to develop the concept of home ehealth centers for barrier-free and cross-border telemedicine. AAL technologies are already present on the market but there is still a gap to close until they can be used for ordinary patient needs. The general idea needs to be accompanied by new services, which should be brought together in order to provide a full coverage of service for the users. Sleep and stress were chosen as predominant diseases for a detailed study within this project because of their widespread influence in the population. The executed scientific study of available home devices analyzing sleep has provided the necessary to select appropriate devices. The first choice for the project implementation is the device EMFIT QS+. This equipment provides a part of a complete system that a home telemedical hospital can provide at a level of precision and communication with internal and/or external health services.
The Industrial Internet of Things (IIoT) will leverage on wireless network technologies to integrate in a seamless manner Cyber-Physical Systems into existing information systems. In this context, the 6TiSCH architecture, proposed by IETF, represents the current leading standardization effort to enable timed and reliable data communication within IPv6 networks for industrial applications. In wireless networks, Link Quality Estimation (LQE) is a crucial task to select the best routes for data forwarding, regardless of unpredictable time varying conditions. Although, many solutions for LQE have been proposed in literature, the majority of them are not designed specifically for 6TiSCH networks. In this paper, we analyze the performance of existing LQE strategies on 6TiSCH networks.
First, we run a set of simulations to measure the performance of one existing LQE strategy in 6TiSCH. Our simulations show that such strategy can result in measurements with low accuracy due to the 6TiSCH default timeslot allocation strategy. Consequently, we propose an extension of the 6TiSCH Minimal Configuration that allocates specific timeslots for the transmission of probing messages to mitigate the problem. The proposed methodology is demonstrated to effectively reduce the LQE error.
The exposure to the light has a great influence on human beings in their everyday life. Various lighting sources produce light that reaches the human eye and influences a rhythmic release of melatonin hormone, that is a sleep promoting factor.
Since the development of new technologies provides more control over illuminance, this work uses an IoT based lighting system to set up dim and bright scenarios. A small study has been performed on the influence of illuminance on sleep latency. The system consists of different light bulbs, sensors and a central bridge which are interconnected like a mesh network. Also, a mobile app has been developed, that allows to adjust the lighting in various rooms. With the help of a ferro-electret sensor, like applied in sleep monitoring systems, a subject’s sleep was monitored. The sensor is placed below the mattress and it collects data, which is stored and processed in a cloud or in other alternative locations.
The research was conducted on healthy young subjects after being previously exposed to the preconfigured illuminance for at least three hours before bedtime. The results indicate correlation between sleep onset latency and exposure to different illuminance before bedtime. In a dimmed environment, the subject fell asleep in average 28% faster compared to the brighter environment.