The importance of sleep for human life is enormous. It affects physical, mental, and psychological health. Therefore, it is vital to recognise sleep disorders in a timely manner in order to be able to initiate therapy. There are two methods for measuring sleep-related parameters - objective and subjective. Whether the substitution of a subjective method for an objective one is possible is investigated in this paper. Such replacement may bring several advantages, including increased comfort for the user. To answer this research question, a study was conducted in which 75 overnight recordings were evaluated. The primary purpose of this study was to compare both ways of measurement for total sleep time and sleep efficiency, which are essential parameters for, e.g., insomnia diagnosis and treatment. The evaluation results demonstrated that, on average, there are 32 minutes of difference between the two measurement methods when total sleep time is analysed. In contrast, on average, both measurement methods differ by 7.5% for sleep efficiency measurement. It should also be noted that people typically overestimate total sleep time and efficiency with the subjective method, where the perceived values are measured.
The influence of sleep on human life, including physiological, psychological, and mental aspects, is remarkable. Therefore, it is essential to apply appropriate therapy in the case of sleep disorders. For this, however, the irregularities must first be recognised, preferably conveniently for the person concerned. This dissertation, structured as a composition of research articles, presents the development of mathematically based algorithmic principles for a sleep analysis system. The particular focus is on the classification of sleep stages with a minimal set of physiological parameters. In addition, the aspects of using the sleep analysis system as part of the more complex healthcare systems are explored. Design of hardware for non-obtrusive measurement of relevant physiological parameters and the use of such systems to detect other sleep disorders, such as sleep apnoea, are also referred to. Multinomial logistic regression was selected as the basis for development resulting from the investigations carried out. By following a methodical procedure, the number of physiological parameters necessary for the classification of sleep stages was successively reduced to two: Respiratory and Movement signals. These signals might be measured in a contactless way. A prototype implementation of the developed algorithms was performed to validate the proposed method, and the evaluation of 19324 sleep epochs was carried out. The results, with the achieved accuracy of 73% in the classification of Wake/NREM/REM stages and Cohen's kappa of 0.44, outperform the state of the art and demonstrate the appropriateness of the selected approach. In the future, this method could enable convenient, cost-effective, and accurate sleep analysis, leading to the detection of sleep disorders at an early stage so that therapy can be initiated as soon as possible, thus improving the general population's health status and quality of life.
Recognition of sleep and wake states is one of the relevant parts of sleep analysis. Performing this measurement in a contactless way increases comfort for the users. We present an approach evaluating only movement and respiratory signals to achieve recognition, which can be measured non-obtrusively. The algorithm is based on multinomial logistic regression and analyses features extracted out of mentioned above signals. These features were identified and developed after performing fundamental research on characteristics of vital signals during sleep. The achieved accuracy of 87% with the Cohen’s kappa of 0.40 demonstrates the appropriateness of a chosen method and encourages continuing research on this topic.
Sleep is an important part of our life that significantly influences our health and well-being. The monitoring of sleep can provide data based on which sleep quality could be improved. This paper presents a system for heart rate detection during sleep. The data is collected from sensors underneath the test subjects. Though the data contains noise, it needs to be filtered to remove it. Due to the low strength of the signals, they need to be amplified after filtering. At some points of the signal, particular heartbeats may not be tracked by sensors due to the failure of a sensor or other reasons, which should be considered. The heart rate is detected in intervals of 15 s. A tool is implemented that detects the heart rate and visualizes it. The preprocessing of the data is performed with several filters: a highpass filter, a band-reject filter, a lowpass filter, and a motion detector. After the preprocessing of the data, the quality of the signal is significantly increased, and detection is possible.
The scoring of sleep stages is an essential part of sleep studies. The main objective of this research is to provide an algorithm for the automatic classification of sleep stages using signals that may be obtained in a non-obtrusive way. After reviewing the relevant research, the authors selected a multinomial logistic regression as the basis for their approach. Several parameters were derived from movement and breathing signals, and their combinations were investigated to develop an accurate and stable algorithm. The algorithm was implemented to produce successful results: the accuracy of the recognition of Wake/NREM/REM stages is equal to 73%, with Cohen's kappa of 0.44 for the analyzed 19324 sleep epochs of 30 seconds each. This approach has the advantage of using the only movement and breathing signals, which can be recorded with less effort than heart or brainwave signals, and requiring only four derived parameters for the calculations. Therefore, the new system is a significant improvement for non-obtrusive sleep stage identification compared to existing approaches.
Sustainable technologies are being increasingly used in various areas of human life. While they have a multitude of benefits, they are especially useful in health monitoring, especially for certain groups of people, such as the elderly. However, there are still several issues that need to be addressed before its use becomes widespread. This work aims to clarify the aspects that are of great importance for increasing the acceptance of the use of this type of technology in the elderly. In addition, we aim to clarify whether the technologies that are already available are able to ensure acceptable accuracy and whether they could replace some of the manual approaches that are currently being used. A two-week study with people 65 years of age and over was conducted to address the questions posed here, and the results were evaluated. It was demonstrated that simplicity of use and automatic functioning play a crucial role. It was also concluded that technology cannot yet completely replace traditional methods such as questionnaires in some areas. Although the technologies that were tested were classified as being “easy to use”, the elderly population in the current study indicated that they were not sure that they would use these technologies regularly in the long term because the added value is not always clear, among other issues. Therefore, awareness-raising must take place in parallel with the development of technologies and services.
The present work proposes the use of modern ICT technologies such as smartphones, NFCs, internet, and web technologies, to help patients in carrying out their therapies. The implemented system provides a calendar with a reminder of the assumptions, ensures the drug identification through NFC, allows remote assistance from healthcare staff and family members to check and manage the therapy in real-time. The system also provides centralized information on the patient's therapeutic situation, helpful in choosing new compatible therapies.
Ballistocardiography (BCG) can be used to monitor heart rate activity. Besides, the accelerometer should have high sensitivity and minimal internal noise; a low-cost approach was taken into consideration. Several measurements have been executed to determine the optimal positioning of a sensor under the mattress to obtain a signal strong enough for further analysis. A prototype for an unobtrusive accelerometer-based measurement system has been developed and tested in a conventional bed without any specific extras. The influence of the human sleep position for the output accelerometer data was tested. The obtained results indicate the potential to capture BCG signals using accelerometers. The measurement system can detect heart rate in an unobtrusive form in the home environment.
The last decades have shown that the volume of tourism, in general, is constantly increasing (with some justified exceptions). To offer a possibility of travel for all groups of people, it is necessary to pay attention to accessibility. One of the possibilities for increasing accessibility is digital technologies, which could assist in planning and the implementation and completion of trips. To make a selection of technologies, first, a study of barriers was conducted, which was then analyzed, and finally, some technologies were made available in a test setup. A focus on two technologies was made: 360°-Tours and mobile app with the travel information. The two technologies were implemented and presented to the test subjects.
The evaluation results showed that both technologies could increase accessibility if some essential aspects (such as usability, completeness, relevance, etc.) are considered during the implementation.
The development of home health systems can provide continuous and user-friendly monitoring of key health parameters. This project aims to create a concept for such a system, implement it on a test basis, and evaluate it. Three health areas were selected for this purpose:
Sleep, Stress, and Rehabilitation. Appropriate devices were installed in the homes of test subjects and used by them for two weeks. Besides, relevant questionnaires were completed to obtain a complete picture. Finally, the implemented system was evaluated, and the results of the conducted study showed that home health systems have great potential. However, it is necessary to consider some points to increase the usability of the system and the motivation of the users. Among others, ease of use of the equipment is of extreme importance.