Refine
Year of publication
Document Type
- Conference Proceeding (103)
- Article (29)
- Other Publications (3)
- Part of a Book (2)
- Report (1)
Keywords
- 1D-CNN (1)
- AAL (3)
- AHI (1)
- Accelerometer (3)
- Accelerometer sensor (2)
- Accelerometers (2)
- Accessibility (1)
- Activity monitoring (1)
- Algorithm (1)
- Ambient assisted living (2)
Institute
The process of restoring our body and brain from fatigue is directly depend-ing on the quality of sleep. It can be determined from the report of the sleep study results. Classification of sleep stages is the first step of this study and this includes the measurement of biovital data and its further processing.
In this work, the sleep analysis system is based on a hardware sensor net, namely a grid of 24 pressure sensors, supporting sleep phase recognition. In comparison to the leading standard, which is polysomnography, the proposed approach is a non-invasive system. It recognises respiration and body move-ment with only one type of low-cost pressure sensors forming a mesh archi-tecture. The nodes implement as a series of pressure sensors connected to a low-power and performant microcontroller. All nodes are connected via a system wide bus with address arbitration. The embedded processor is the mesh network endpoint that enables network configuration, storing and pre-processing of the data, external data access and visualization.
The system was tested by executing experiments recording the sleep of different healthy young subjects. The results obtained have indicated the po-tential to detect breathing rate and body movement. A major difference of this system in comparison to other approaches is the innovative way to place the sensors under the mattress. This characteristic facilitates the continuous using of the system without any influence on the common sleep process.
In recent decades, it can be observed that a steady increase in the volume of tourism is a stable trend. To offer travel opportunities to all groups, it is also necessary to prepare offers for people in need of long-term care or people with disabilities. One of the ways to improve accessibility could be digital technologies, which could help in planning as well as in carrying out trips. In the work presented, a study of barriers was first conducted, which led to selecting technologies for a test setup after analysis. The main focus was on a mobile app with travel information and 360° tours. The evaluation results showed that both technologies could increase accessibility, but some essential aspects (such as usability, completeness, relevance, etc.) need to be considered when implementing them.
Normal breathing during sleep is essential for people’s health and well-being. Therefore, it is crucial to diagnose apnoea events at an early stage and apply appropriate therapy. Detection of sleep apnoea is a central goal of the system design described in this article. To develop a correctly functioning system, it is first necessary to define the requirements outlined in this manuscript clearly. Furthermore, the selection of appropriate technology for the measurement of respiration is of great importance. Therefore, after performing initial literature research, we have analysed in detail three different methods and made a selection of a proper one according to determined requirements. After considering all the advantages and disadvantages of the three approaches, we decided to use the impedance measurement-based one. As a next step, an initial conceptual design of the algorithm for detecting apnoea events was created. As a result, we developed an activity diagram on which the main system components and data flows are visually represented.
Polysomnography is a gold standard for a sleep study, and it provides very accurate results, but its cost (both personnel and material) are quite high. Therefore, the development of a low-cost system for overnight breathing and heartbeat monitoring, which provides more comfort while recording the data, is a well-motivated challenge. The system proposed in this manuscript is based on the usage of resistive pressure sensors installed under the mattress. These sensors can measure slight pressure changes provoked during breathing and heartbeat. The captured signal requires advanced processing, like applying filters and amplifiers before the analog signal is ready for the next step. Then, the output signal is digitalized and further processed by an algorithm that performs a custom filtering before it can recognize breathing and heart rate in real-time. The result can be directly visualized. Furthermore, a CSV file is created containing the raw data, timestamps, and unique IDs to facilitate further processing. The achieved results are promising, and the average deviation from a reference device is about 4bpm.
The person’s heart rate is an important indicator of their health status. A heart rate that is too high or too low could be a sign of several different diseases, such as a heart disorder, obesity, asthma, or many others. Many devices require users to wear the device on their chest or place a finger on the device. The approach presented in this paper describes the principle and implementation of a heart rate monitoring device, which is able to detect the heart rate with high precision with the sensor integrated in a wristband. One method to measure the heart rate is the photoplethysmogram technique. This method measures the change of blood volume through the absorption or reflection of light. A light emitting diode (LED) shines through a thin amount of tissue. A photo-diode registers the intensity of light that traverses the tissue or is reflected by the tissue. Since blood changes its volume with each heartbeat, the photo-diode detects more or less light from the LED. The device is able to measure the heart rate with a high precision, it has low performance and hardware requirements, and it allows an implementation with small micro-controllers.
Fatigue and drowsiness are responsible for a significant percentage of road traffic accidents. There are several approaches to monitor the driver’s drowsiness, ranging from the driver’s steering behavior to analysis of the driver, e.g. eye tracking, blinking, yawning or electrocardiogram (ECG). This paper describes the development of a low-cost ECG sensor to derive heart rate variability (HRV) data for the drowsiness detection. The work includes the hardware and the software design. The hardware has been implemented on a printed circuit board (PCB) designed so that the board can be used as an extension shield for an Arduino. The PCB contains a double, inverted ECG channel including low-pass filtering and provides two analog outputs to the Arduino, that combined them and performs the analog-to-digital conversion. The digital ECG signal is transferred to an NVidia embedded PC where the processing takes place, including QRS-complex, heart rate and HRV detection as well as visualization features. The compact resulting sensor provides good results in the extraction of the main ECG parameters. The sensor is being used in a larger frame, where facial-recognition-based drowsiness detection is combined with ECG-based detection to improve the recognition rate under unfavorable light or occlusion conditions.
Sleep disorders can impact daily life, affecting physical, emotional, and cognitive well-being. Due to the time-consuming, highly obtrusive, and expensive nature of using the standard approaches such as polysomnography, it is of great interest to develop a noninvasive and unobtrusive in-home sleep monitoring system that can reliably and accurately measure cardiorespiratory parameters while causing minimal discomfort to the user’s sleep. We developed a low-cost Out of Center Sleep Testing (OCST) system with low complexity to measure cardiorespiratory parameters. We tested and validated two force-sensitive resistor strip sensors under the bed mattress covering the thoracic and abdominal regions. Twenty subjects were recruited, including 12 males and 8 females. The ballistocardiogram signal was processed using the 4th smooth level of the discrete wavelet transform and the 2nd order of the Butterworth bandpass filter to measure the heart rate and respiration rate, respectively. We reached a total error (concerning the reference sensors) of 3.24 beats per minute and 2.32 rates for heart rate and respiration rate, respectively. For males and females, heart rate errors were 3.47 and 2.68, and respiration rate errors were 2.32 and 2.33, respectively. We developed and verified the reliability and applicability of the system. It showed a minor dependency on sleeping positions, one of the major cumbersome sleep measurements. We identified the sensor under the thoracic region as the optimal configuration for cardiorespiratory measurement. Although testing the system with healthy subjects and regular patterns of cardiorespiratory parameters showed promising results, further investigation is required with the bandwidth frequency and validation of the system with larger groups of subjects, including patients.
Apnea is a sleep disorder characterized by breathing interruptions during sleep, impacting cardiorespiratory function and overall health. Traditional diagnostic methods, like polysomnography (PSG), are unobtrusive, leading to noninvasive monitoring. This study aims to develop and validate a novel sleep monitoring system using noninvasive sensor technology to estimate cardiorespiratory parameters and detect sleep apnea. We designed a seamless monitoring system integrating noncontact force-sensitive resistor sensors to collect ballistocardiogram signals associated with cardiorespiratory activity. We enhanced the sensor’s sensitivity and reduced the noise by designing a new concept of edge-measuring sensor using a hemisphere dome and mechanical hanger to distribute the force and mechanically amplify the micromovement caused by cardiac and respiration activities. In total, we deployed three edge-measuring sensors, two deployed under the thoracic and one under the abdominal regions. The system is supported with onboard signal preprocessing in multiple physical layers deployed under the mattress. We collected the data in four sleeping positions from 16 subjects and analyzed them using ensemble empirical mode decomposition (EMD) to avoid frequency mixing. We also developed an adaptive thresholding method to identify sleep apnea. The error was reduced to 3.98 and 1.43 beats/min (BPM) in heart rate (HR) and respiration estimation, respectively. The apnea was detected with an accuracy of 87%. We optimized the system such that only one edge-measuring sensor can measure the cardiorespiratory parameters. Such a reduction in the complexity and simplification of the instruction of use shows excellent potential for in-home and continuous monitoring.
Sleep is essential to existence, much like air, water, and food, as we spend nearly one-third of our time sleeping. Poor sleep quality or disturbed sleep causes daytime solemnity, which worsens daytime activities' mental and physical qualities and raises the risk of accidents. With advancements in sensor and communication technology, sleep monitoring is moving out of specialized clinics and into our everyday homes. It is possible to extract data from traditional overnight polysomnographic recordings using more basic tools and straightforward techniques. Ballistocardiogram is an unobtrusive, non-invasive, simple, and low-cost technique for measuring cardiorespiratory parameters. In this work, we present a sensor board interface to facilitate the communication between force sensitive resistor sensor and an embedded system to provide a high-performing prototype with an efficient signal-to-noise ratio. We have utilized a multi-physical-layer approach to locate each layer on top of another, yet supporting a low-cost, compact design with easy deployment under the bed frame.
The proposed approach applies current unsupervised clustering approaches in a different dynamic manner. Instead of taking all the data as input and finding clusters among them, the given approach clusters Holter ECG data (long-term electrocardiography data from a holter monitor) on a given interval which enables a dynamic clustering approach (DCA). Therefore advanced clustering techniques based on the well known Dynamic Time Warping algorithm are used. Having clusters e.g. on a daily basis, clusters can be compared by defining cluster shape properties. Doing this gives a measure for variation in unsupervised cluster shapes and may reveal unknown changes in healthiness. Embedding this approach into wearable devices offers advantages over the current techniques. On the one hand users get feedback if their ECG data characteristic changes unforeseeable over time which makes early detection possible. On the other hand cluster properties like biggest or smallest cluster may help a doctor in making diagnoses or observing several patients. Further, on found clusters known processing techniques like stress detection or arrhythmia classification may be applied.
The exposure to the light has a great influence on human beings in their everyday life. Various lighting sources produce light that reaches the human eye and influences a rhythmic release of melatonin hormone, that is a sleep promoting factor.
Since the development of new technologies provides more control over illuminance, this work uses an IoT based lighting system to set up dim and bright scenarios. A small study has been performed on the influence of illuminance on sleep latency. The system consists of different light bulbs, sensors and a central bridge which are interconnected like a mesh network. Also, a mobile app has been developed, that allows to adjust the lighting in various rooms. With the help of a ferro-electret sensor, like applied in sleep monitoring systems, a subject’s sleep was monitored. The sensor is placed below the mattress and it collects data, which is stored and processed in a cloud or in other alternative locations.
The research was conducted on healthy young subjects after being previously exposed to the preconfigured illuminance for at least three hours before bedtime. The results indicate correlation between sleep onset latency and exposure to different illuminance before bedtime. In a dimmed environment, the subject fell asleep in average 28% faster compared to the brighter environment.
To assess the quality of a person’s sleep, it is essential to examine the sleep behaviour by identifying the several sleep stages, their durations and sleep cycles. The established and gold standard procedure for sleep stage scoring is overnight polysomnography (PSG) with the Rechtschaffen and Kales (R-K) method. Unfortunately, the conduct of PSG is timeconsuming and unfamiliar for the subjects and might have an impact of the recorded data. To avoid the disadvantages with PSG, it is important to make further investigations in low-cost home diagnostic systems. For this intention it is necessary to find suitable bio vital parameters for classifying sleep stages without any physical impairments at the same time.
Due to the promising results in several publications we want to analyse existing methods for sleep stage classification based on the parameters body movement,
heartbeat and respiration. Our aim was to find different behaviour patterns in the several sleep stages. Therefore, the average values of 15 wholenight PSG recordings -obtained from the ‘DREAMS Subjects Database’- where analysed in the light of heartbeat, body movement and respiration with 10 different methods.
To evaluate the quality of a person's sleep it is essential to identify the sleep stages and their durations. Currently, the gold standard in terms of sleep analysis is overnight polysomnography (PSG), during which several techniques like EEG (eletroencephalogram), EOG (electrooculogram), EMG (electromyogram), ECG (electrocardiogram), SpO2 (blood oxygen saturation) and for example respiratory airflow and respiratory effort are recorded. These expensive and complex procedures, applied in sleep laboratories, are invasive and unfamiliar for the subjects and it is a reason why it might have an impact on the recorded data. These are the main reasons why low-cost home diagnostic systems are likely to be advantageous. Their aim is to reach a larger population by reducing the number of parameters recorded. Nowadays, many wearable devices promise to measure sleep quality using only the ECG and body-movement signals. This work presents an android application developed in order to proof the accuracy of an algorithm published in the sleep literature. The algorithm uses ECG and body movement recordings to estimate sleep stages. The pre-recorded signals fed into the algorithm have been taken from physionet1 online database. The obtained results have been compared with those of the standard method used in PSG. The mean agreement ratios between the sleep stages REM, Wake, NREM-1, NREM-2 and NREM-3 were 38.1%, 14%, 16%, 75% and 54.3%.
Background:
One of the most promising health care development areas is introducing telemedicine services and creating solutions based on blockchain technology. The study of systems combining both these domains indicates the ongoing expansion of digital technologies in this market segment.
Objective:
This paper aims to review the feasibility of blockchain technology for telemedicine.
Methods:
The authors identified relevant studies via systematic searches of databases including PubMed, Scopus, Web of Science, IEEE Xplore, and Google Scholar. The suitability of each for inclusion in this review was assessed independently. Owing to the lack of publications, available blockchain-based tokens were discovered via conventional web search engines (Google, Yahoo, and Yandex).
Results:
Of the 40 discovered projects, only 18 met the selection criteria. The 5 most prevalent features of the available solutions (N=18) were medical data access (14/18, 78%), medical service processing (14/18, 78%), diagnostic support (10/18, 56%), payment transactions (10/18, 56%), and fundraising for telemedical instrument development (5/18, 28%).
Conclusions:
These different features (eg, medical data access, medical service processing, epidemiology reporting, diagnostic support, and treatment support) allow us to discuss the possibilities for integration of blockchain technology into telemedicine and health care on different levels. In this area, a wide range of tasks can be identified that could be accomplished based on digital technologies using blockchains.
Generating synthetic data is a relevant point in the machine learning community. As accessible data is limited, the generation of synthetic data is a significant point in protecting patients' privacy and having more possibilities to train a model for classification or other machine learning tasks. In this work, some generative adversarial networks (GAN) variants are discussed, and an overview is given of how generative adversarial networks can be used for data generation in different fields. In addition, some common problems of the GANs and possibilities to avoid them are shown. Different evaluation methods of the generated data are also described.
Due to the rising need for palliative care in Russia, it is crucial to provide timely and high-quality solutions for patients, relatives, and caregivers. A methodology for remote monitoring of patients in need of palliative care and the requirements will be developed for a hardware-software complex for remote monitoring of patients' health at home.
Autismus-Spektrum-Störungen (ASD) bei Kindern werden häufig zu spät diagnostiziert und die Begleitung der chronischen Krankheit gestaltet sich schwierig. Der vorgestellte Ansatz erlaubt die Behandlung der Kinder in dem bekannten häuslichen Umfeld und versucht die Beziehungen zwischen Schlaf und Verhalten herauszuarbeiten. Die gewonnenen Erkenntnisse sollen die Lebensqualität der Patienten verbessern und den Eltern Hilfestellung geben. Die notwendige infrastrukturelle Unterstützung wird durch medizinisches Fachpersonal geleistet, das auf einen web-basierten Service zurückgreifen kann, der sämtliche Prozesse (Diagnostik, Datenerfassung, -aufzeichnung und Training etc.) begleitet. Die anonymisierten Daten werden in einem Diagnosesystem zentral abgelegt und können so für zukünftige Behandlungsstrategien nutzbar sein. Die umfassende Lösung setzt auf zentrale Elemente von Smart-Homes und AAL auf.
Unintrusive health monitoring systems is important when continuous monitoring of the patient vital signals is required. In this paper, signals obtained from accelerometers placed under a bed are processed with ballistocardiography algorithms and compared with synchronized electrocardiographic signals.
Preliminary results of homomorphic deconvolution application to surface EMG signals during walking
(2021)
Homomorphic deconvolution is applied to sEMG signals recorded during walking. Gastrocnemius lateralis and tibialis anterior signals were acquired according to SENIAM recommendation. MUAP parameters like amplitude and scale were estimated, whilst the MUAP shape parameter was fixed. This features a useful time-frequency representation of sEMG signal. Estimation of scale MUAP parameter was verified extracting the mean frequency of filtered EMG signal, extracted from the scale parameter estimated with two different MUAP shape values.
The present work proposes the use of modern ICT technologies such as smartphones, NFCs, internet, and web technologies, to help patients in carrying out their therapies. The implemented system provides a calendar with a reminder of the assumptions, ensures the drug identification through NFC, allows remote assistance from healthcare staff and family members to check and manage the therapy in real-time. The system also provides centralized information on the patient's therapeutic situation, helpful in choosing new compatible therapies.
These days computer analysis of ECG (Electrocardiograms) signals is common. There are many real-time QRS recognition algorithms; one of these algorithms is Pan-Tompkins Algorithm. Which the Pan-Tompkins Algorithm can detect QRS complexes of ECG signals. The proposed algorithm is analysed the data stream of the heartbeat based on the digital analysis of the amplitude, the bandwidth, and the slope. In addition to that, the stress algorithm compares whether the current heartbeat is similar or different to the last heartbeat after detecting the ECG signals. This algorithm determines the stress detection for the patient on the real-time. In order to implement the new algorithm with higher performance, the parallel programming language CUDA is used. The algorithm determines stress at the same time by determining the RR interval. The algorithm uses a different function as beat detector and a beat classifier of stress.
The overall goal of this work is to detect and analyze a person's movement, breathing and heart rate during sleep in a common bed overnight without any additional physical contact. The measurement is performed with the help of
sensors placed between the mattress and the frame. A two-stage pattern classification algorithm based has been implemented that applies statistics analysis to recognize the position of patients. The system is implemented in a sensors-network, hosting several nodes and communication end-points to support quick and efficient classification. The overall tests show convincing results for the position recognition and a reasonable overlap in matching.
The goal of this paper pretends to show how a bed system with an embedded system with sensor is able to analyze a person’s movement, breathing and recognizing the positions that the subject is lying on the bed during the night without any additional physical contact. The measurements are performed with sensors placed between the mattress and the frame. An Intel Edison board was used as an endpoint that served as a communication node from the mesh network to external service. Two nodes and Intel Edison are attached to the bottom of the bed frame and they are connected to the sensors.
Deep Learning-based EEG Detection of Mental Alertness States from Drivers under Ethical Aspects
(2022)
One of the most critical factors for a successful road trip is a high degree of alertness while driving. Even a split second of inattention or sleepiness in a crucial moment, will make the difference between life and death. Several prestigious car manufacturers are currently pursuing the aim of automated drowsiness identification to resolve this problem. The path between neuro-scientific research in connection with artificial intelligence and the preservation of the dignity of human individual’s and its inviolability, is very narrow. The key contribution of this work is a system of data analysis for EEGs during a driving session, which draws on previous studies analyzing heart rate (ECG), brain waves (EEG), and eye function (EOG). The gathered data is hereby treated as sensitive as possible, taking ethical regulations into consideration. Obtaining evaluable signs of evolving exhaustion includes techniques that obtain sleeping stage frequencies, problematic are hereby the correlated interference’s in the signal. This research focuses on a processing chain for EEG band splitting that involves band-pass filtering, principal component analysis (PCA), independent component analysis (ICA) with automatic artefact severance, and fast fourier transformation (FFT). The classification is based on a step-by-step adaptive deep learning analysis that detects theta rhythms as a drowsiness predictor in the pre-processed data. It was possible to obtain an offline detection rate of 89% and an online detection rate of 73%. The method is linked to the simulated driving scenario for which it was developed. This leaves space for more optimization on laboratory methods and data collection during wakefulness-dependent operations.
Sleep is an important part of our life that significantly influences our health and well-being. The monitoring of sleep can provide data based on which sleep quality could be improved. This paper presents a system for heart rate detection during sleep. The data is collected from sensors underneath the test subjects. Though the data contains noise, it needs to be filtered to remove it. Due to the low strength of the signals, they need to be amplified after filtering. At some points of the signal, particular heartbeats may not be tracked by sensors due to the failure of a sensor or other reasons, which should be considered. The heart rate is detected in intervals of 15 s. A tool is implemented that detects the heart rate and visualizes it. The preprocessing of the data is performed with several filters: a highpass filter, a band-reject filter, a lowpass filter, and a motion detector. After the preprocessing of the data, the quality of the signal is significantly increased, and detection is possible.
A significant proportion of road traffic accidents are due to inattentiveness or fatigue at the wheel. Approaches to monitoring the driver's condition range from eye tracking and driving behavior analysis to yawn and blink detection and ECG measurement. This work describes the development of a mobile system for the measurement and processing of ECG data. The aim of the signal processing is to quantify the driver’s fatigue with the heartrate variability (HRV). The work includes the hardware and software design of the sensor. First, the development of low-noise electronics including AD conversion is described. Then the software signal processing with QRS complex detection and plotting front end is explained. The resulting sensor is compact, low-cost and provides a good signal for HRV extraction.
The number of home office workers sitting for many hours is increasing. The sensor chair is tracking users’ sitting behavior which the help of pressure sensors and tries to avoid wrong postures which may cause diseases. The system provides live monitoring of the pressure distribution via web interface, as well as sitting posture prediction in real time. Posture analysis is realized through machine learning algorithm using a decision tree classifier that is compared to a random forest. Data acquisition and aggregation for the learning process happens with a mobile app adding users biometrical data and the taken sitting posture as label. The sensor chair is able to differentiate between an arched back, a neutral posture or a laid back position taken on the chair. The classifier achieves an accuracy of 97.4% on our test set and is comparable to the performance of the random forest with 98.9%.
Cardiovascular diseases are directly or indirectly responsible for up to 38.5% of all deaths in Germany and thus represent the most frequent cause of death. At present, heart diseases are mainly discovered by chance during routine visits to the doctor or when acute symptoms occur. However, there is no practical method to proactively detect diseases or abnormalities of the heart in the daily environment and to take preventive measures for the person concerned. Long-term ECG devices, as currently used by physicians, are simply too expensive, impractical, and not widely available for everyday use. This work aims to develop an ECG device suitable for everyday use that can be worn directly on the body. For this purpose, an already existing hardware platform will be analyzed, and the corresponding potential for improvement will be identified. A precise picture of the existing data quality is obtained by metrological examination, and corresponding requirements are defined. Based on these identified optimization potentials, a new ECG device is developed. The revised ECG device is characterized by a high integration density and combines all components directly on one board except the battery and the ECG electrodes. The compact design allows the device to be attached directly to the chest. An integrated microcontroller allows digital signal processing without the need for an additional computer. Central features of the evaluation are a peak detection for detecting R-peaks and a calculation of the current heart rate based on the RR interval. To ensure the validity of the detected R-peaks, a model of the anatomical conditions is used. Thus, unrealistic RR-intervals can be excluded. The wireless interface allows continuous transmission of the calculated heart rate. Following the development of hardware and software, the results are verified, and appropriate conclusions about the data quality are drawn. As a result, a very compact and wearable ECG device with different wireless technologies, data storage, and evaluation of RR intervals was developed. Some tests yelled runtimes up to 24 hours with wireless Lan activated and streaming.
While driving, stress is caused by situations in which the driver estimates their ability to manage the driving demands as insufficient or loses the capability to handle the situation. This leads to increased numbers of driver mistakes and traffic violations. Additional stressing factors are time pressure, road conditions, or dislike for driving. Therefore, stress affects driver and road safety. Stress is classified into two categories depending on its duration and the effects on the body and psyche: short-term eustress and constantly present distress, which causes degenerative effects. In this work, we focus on distress. Wearable sensors are handy tools for collecting biosignals like heart rate, activity, etc. Easy installation and non-intrusive nature make them convenient for calculating stress. This study focuses on the investigation of stress and its implications. Specifically, the research conducts an analysis of stress within a select group of individuals from both Spain and Germany. The primary objective is to examine the influence of recognized psychological factors, including personality traits such as neuroticism, extroversion, psychoticism, stress and road safety. The estimation of stress levels was accomplished through the collection of physiological parameters (R-R intervals) using a Polar H10 chest strap. We observed that personality traits, such as extroversion, exhibited similar trends during relaxation, with an average heart rate 6% higher in Spain and 3% higher in Germany. However, while driving, introverts, on average, experienced more stress, with rates 4% and 1% lower than extroverts in Spain and Germany, respectively.
In previous studies, we used a method for detecting stress that was based exclusively on heart rate and ECG for differentiation between such situations as mental stress, physical activity, relaxation, and rest. As a response of the heart to these situations, we observed different behavior in the Root Mean Square of the Successive differences heartbeats (RMSSD). This study aims to analyze Virtual Reality via a virtual reality headset as an effective stressor for future works. The value of the Root Mean Square of the Successive Differences is an important marker for the parasympathetic effector on the heart and can provide information about stress. For these measurements, the RR interval was collected using a breast belt. In these studies, we can observe the Root Mean Square of the successive differences heartbeats. Additional sensors for the analysis were not used. We conducted experiments with ten subjects that had to drive a simulator for 25 minutes using monitors and 25 minutes using virtual reality headset. Before starting and after finishing each simulation, the subjects had to complete a survey in which they had to describe their mental state. The experiment results show that driving using virtual reality headset has some influence on the heart rate and RMSSD, but it does not significantly increase the stress of driving.
To evaluate the quality of sleep, it is important to determine how much time was spent in each sleep stage during the night. The gold standard in this domain is an overnight polysomnography (PSG). But the recording of the necessary electrophysiological signals is extensive and complex and the environment of the sleep laboratory, which is unfamiliar to the patient, might lead to distorted results. In this paper, a sleep stage detection algorithm is proposed that uses only the heart rate signal, derived from electrocardiogram (ECG), as a discriminator. This would make it possible for sleep analysis to be performed at home, saving a lot of effort and money. From the heart rate, using the fast Fourier transformation (FFT), three parameters were calculated in order to distinguish between the different sleep stages. ECG data along with a hypnogram scored by professionals was used from Physionet database, making it easy to compare the results. With an agreement rate of 41.3%, this approach is a good foundation for future research.
Stress is recognized as a factor of predominant disease and in the future the costs for treatment will increase. The presented approach tries to detect stress in a very basic and easy to implement way, so that the cost for the device and effort to wear it remain low. The user should benefit from the fact that the system offers an easy interface reporting the status of his body in real time. In parallel, the system provides interfaces to pass the obtained data forward for further processing and (professional) analyses, in case the user agrees. The system is designed to be used in every day’s activities and it is not restricted to laboratory use or environments. The implementation of the enhanced prototype shows that the detection of stress and the reporting can be managed using correlation plots and automatic pattern recognition even on a very light-weighted microcontroller platform.
Stress and physical activities are important aspects of life of people. Body reactions on stress and on physical activities can be very similar but long-term stress leads to diseases and damages the body. Currently there is no method to differentiate easily and clearly between these two aspects in a time slot. We have confronted this problem while developing a mobile system for detection and analysis of stress. This paper presents an approach, which uses a long-term monitor with ECG/EKG capabilities and analysis of the heart rate data that is extracted from the device. The focus of the work is to find characteristics that are useful for differentiation between physical activity and stress.
Stress is recognized as a predominant disease with raising costs for rehabilitation and treatment. Currently there several different approaches that can be used for determining and calculating the stress levels. Usually the methods for determining stress are divided in two categories. The first category do not require any special equipment for measuring the stress. This category useless the variation in the behaviour patterns that occur while stress. The core disadvantage for the category is their limitation to specific use case. The second category uses laboratories instruments and biological sensors. This category allow to measure stress precisely and proficiently but on the same time they are not mobile and transportable and do not support real-time feedback. This work presents a mobile system that provides the calculation of stress. For achieving this, the of a mobile ECG sensor is analysed, processed and visualised over a mobile system like a smartphone. This work also explains the used stress measurement algorithm. The result of this work is a portable system that can be used with a mobile system like a smartphone as visual interface for reporting the current stress level.
The perception of the amount of stress is subjective to every person, and the perception of it changes depending on many factors. One of the factors that has an impact on perceived stress is the emotional state. In this work, we compare the emotional state of 40 German driving students and present different partitions that can be advantageous for using artificial intelligence and classification. Like this, we evaluate the data quality and prepare for the specific use. The Stress Perceived Questionnaire (PSQ20) was employed to assess the level of stress experienced by individuals while participating in a driving simulation for 5 and 25 min. As a result of our analysis, we present a categorisation of various emotional states into intervals, comparing different classifications and facilitating a more straightforward implementation of artificial intelligence for classification purposes.
The investigation of stress requires to distinguish between stress caused by physical activity and stress that is caused by psychosocial factors. The behaviour of the heart in response to stress and physical activity is very similar in case the set of monitored parameters is reduced to one. Currently, the differentiation remains difficult and methods which only use the heart rate are not able to differentiate between stress and physical activity, without using additional sensor data input. The approach focusses on methods which generate signals providing characteristics that are useful for detecting stress, physical activity, no activity and relaxation.
Methods based exclusively on heart rate hardly allow to differentiate between physical activity, stress, relaxation, and rest, that is why an additional sensor like activity/movement sensor added for detection and classification. The response of the heart to physical activity, stress, relaxation, and no activity can be very similar. In this study, we can observe the influence of induced stress and analyze which metrics could be considered for its detection. The changes in the Root Mean Square of the Successive Differences provide us with information about physiological changes. A set of measurements collecting the RR intervals was taken. The intervals are used as a parameter to distinguish four different stages. Parameters like skin conductivity or skin temperature were not used because the main aim is to maintain a minimum number of sensors and devices and thereby to increase the wearability in the future.
The purpose of this paper is to examine the effects of perceived stress on traffic and road safety. One of the leading causes of stress among drivers is the feeling of having a lack of control during the driving process. Stress can result in more traffic accidents, an increase in driver errors, and an increase in traffic violations. To study this phenomenon, the Stress Perceived Questionnaire (PSQ) was used to evaluate the perceived stress while driving in a simulation. The study was conducted with participants from Germany, and they were grouped into different categories based on their emotional stability. Each participant was monitored using wearable devices that measured their instantaneous heart rate (HR). The preference for wearable devices was due to their non-intrusive and portable nature. The results of this study provide an overview of how stress can affect traffic and road safety, which can be used for future research or to implement strategies to reduce road accidents and promote traffic safety.
The principal objective of this study is to investigate the impact of perceived stress on traffic and road safety. Therefore, we designed a study that allows the generation and collection of stress-relevant data. Drivers often experience stress due to their perception of lack of control during the driving process. This can lead to an increased likelihood of traffic accidents, driver errors, and traffic violations. To explore this phenomenon, we used the Stress Perceived Questionnaire (PSQ) to evaluate perceived stress levels during driving simulations and the EPQR questionnaire to determine the personality of the driver. With the presented study, participants can categorised based on their emotional stability and personality traits. Wearable devices were utilised to monitor each participant's instantaneous heart rate (HR) due to their non-intrusive and portable nature. The findings of this study deliver an overview of the link between stress and traffic and road safety. These findings can be utilised for future research and implementing strategies to reduce road accidents and promote traffic safety.
Stress is a recognized as a predominant disease with growing costs of treatment. The approach presented here is aimed to detect stress using a light weighted, mobile, cheap and easy to use system. The result shows that stress can be detected even in case a person’s natural bio vital data is out of the main range. The system enables storage of measured data, while maintaining communication channels of online and post-processing.