This paper compares two popular scripting implementations for hardware prototyping: Python scripts exe- cut from User-Space and C-based Linux-Driver processes executed from Kernel-Space, which can provide information to researchers when considering one or another in their implementations. Conclusions exhibit that deploying software scripts in the kernel space makes it possible to grant a certain quality of sensor information using a Raspberry Pi without the need for advanced real-time operational systems.
Monitoring heart rate and breathing is essential in understanding the physiological processes for sleep analysis. Polysomnography (PSG) system have traditionally been used for sleep monitoring, but alternative methods can help to make sleep monitoring more portable in someone's home. This study conducted a series of experiments to investigate the use of pressure sensors placed under the bed as an alternative to PSG for monitoring heart rate and breathing during sleep. The following sets of experiments involved the addition of small rubber domes - transparent and black - that were glued to the pressure sensor. The resulting data were compared with the PSG system to determine the accuracy of the pressure sensor readings. The study found that the pressure sensor provided reliable data for extracting heart rate and respiration rate, with mean absolute errors (MAE) of 2.32 and 3.24 for respiration and heart rate, respectively. However, the addition of small rubber hemispheres did not significantly improve the accuracy of the readings, with MAEs of 2.3 bpm and 7.56 breaths per minute for respiration rate and heart rate, respectively. The findings of this study suggest that pressure sensors placed under the bed may serve as a viable alternative to traditional PSG systems for monitoring heart rate and breathing during sleep. These sensors provide a more comfortable and non-invasive method of sleep monitoring. However, the addition of small rubber domes did not significantly enhance the accuracy of the readings, indicating that it may not be a worthwhile addition to the pressure sensor system.
Sleep is a multi-dimensional influencing factor on physical health, cognitive function, emotional well-being, mental health, daily performance, and productivity. The barriers such as time-consuming, invasiveness, and expense have caused a gradual shift in sleep monitoring from traditional and standard in-lab approach, e. g., polysomnography (PSG) to unobtrusive and noninvasive in-home sleep monitoring, yet further improvement is required. Despite an increasing interest in fiberoptic-based methods for cardiorespiratory estimation, the traditional mechanical-based sensors consist of force-sensitive resistors (FSR), lead zirconate titanate piezoelectric (PZT), and accelerometers yet serve as the dominant approach. The part of popularity lies in reducing the system’s complexity, expense, easy maintenance, and user-friendliness. However, care must be taken regarding the performance of such sensors with respect to accuracy and calibration.
The massive use of patient data for the training of artificial intelligence algorithms is common nowadays in medicine. In this scientific work, a statistical analysis of one of the most used datasets for the training of artificial intelligence models for the detection of sleep disorders is performed: sleep health heart study 2. This study focuses on determining whether the gender and age of the patients have a relevant influence to consider working with differentiated datasets based on these variables for the training of artificial intelligence models.
Measuring cardiorespiratory parameters in sleep, using non-contact sensors and the Ballistocardiography technique has received much attention due to the low-cost, unobtrusive, and non-invasive method. Designing a user-friendly, simple-to-use, and easy-to-deployment preserving less errorprone remains open and challenging due to the complex morphology of the signal. In this work, using four forcesensitive resistor sensors, we conducted a study by designing four distributions of sensors, in order to simplify the complexity of the system by identifying the region of interest for heartbeat and respiration measurement. The sensors are deployed under the mattress and attached to the bed frame without any interference with the subjects. The four distributions are combined in two linear horizontal, one linear vertical, and one square, covering the influencing region in cardiorespiratory activities. We recruited 4 subjects and acquired data in four regular sleeping positions, each for a duration of 80 seconds. The signal processing was performed using discrete wavelet transform bior 3.9 and smooth level of 4 as well as bandpass filtering. The results indicate that we have achieved the mean absolute error of 2.35 and 4.34 for respiration and heartbeat, respectively. The results recommend the efficiency of a triangleshaped structure of three sensors for measuring heartbeat and respiration parameters in all four regular sleeping positions.
Accurate monitoring of a patient's heart rate is a key element in the medical observation and health monitoring. In particular, its importance extends to the identification of sleep-related disorders. Various methods have been established that involve sensor-based recording of physiological signals followed by automated examination and analysis. This study attempts to evaluate the efficacy of a non-invasive HR monitoring framework based on an accelerometer sensor specifically during sleep. To achieve this goal, the motion induced by thoracic movements during cardiac contractions is captured by a device installed under the mattress. Signal filtering techniques and heart rate estimation using the symlets6 wavelet are part of the implemented computational framework described in this article. Subsequent analysis indicates the potential applicability of this system in the prognostic domain, with an average error margin of approximately 3 beats per minute. The results obtained represent a promising advancement in non-invasive heart rate monitoring during sleep, with potential implications for improved diagnosis and management of cardiovascular and sleep-related disorders.
The principal objective of this study is to investigate the impact of perceived stress on traffic and road safety. Therefore, we designed a study that allows the generation and collection of stress-relevant data. Drivers often experience stress due to their perception of lack of control during the driving process. This can lead to an increased likelihood of traffic accidents, driver errors, and traffic violations. To explore this phenomenon, we used the Stress Perceived Questionnaire (PSQ) to evaluate perceived stress levels during driving simulations and the EPQR questionnaire to determine the personality of the driver. With the presented study, participants can categorised based on their emotional stability and personality traits. Wearable devices were utilised to monitor each participant's instantaneous heart rate (HR) due to their non-intrusive and portable nature. The findings of this study deliver an overview of the link between stress and traffic and road safety. These findings can be utilised for future research and implementing strategies to reduce road accidents and promote traffic safety.
Development of an expert system to overpass citizens technological barriers on smart home and living
(2023)
Adopting new technologies can be overwhelming, even for people with experience in the field. For the general public, learning about new implementations, releases, brands, and enhancements can cause them to lose interest. There is a clear need to create point sources and platforms that provide helpful information about the novel and smart technologies, assisting users, technicians, and providers with products and technologies. The purpose of these platforms is twofold, as they can gather and share information on interests common to manufacturers and vendors. This paper presents the ”Finde-Dein-SmartHome” tool. Developed in association with the Smart Home & Living competence center [5] to help users learn about, understand, and purchase available technologies that meet their home automation needs. This tool aims to lower the usability barrier and guide potential customers to clear their doubts about privacy and pricing. Communities can use the information provided by this tool to identify market trends that could eventually lower costs for providers and incentivize access to innovative home technologies and devices supporting long-term care.
Unintrusive health monitoring systems is important when continuous monitoring of the patient vital signals is required. In this paper, signals obtained from accelerometers placed under a bed are processed with ballistocardiography algorithms and compared with synchronized electrocardiographic signals.
Healthy sleep is one of the prerequisites for a good human body and brain condition, including general well-being. Unfortunately, there are several sleep disorders that can negatively affect this. One of the most common is sleep apnoea, in which breathing is impaired. Studies have shown that this disorder often remains undiagnosed. To avoid this, developing a system that can be widely used in a home environment to detect apnoea and monitor the changes once therapy has been initiated is essential. The conceptualisation of such a system is the main aim of this research. After a thorough analysis of the available literature and state of the art in this area of knowledge, a concept of the system was created, which includes the following main components: data acquisition (including two parts), storage of the data, apnoea detection algorithm, user and device management, data visualisation. The modules are interchangeable, and interfaces have been defined for data transfer, most of which operate using the MQTT protocol. System diagrams and detailed component descriptions, including signal requirements and visualisation mockups, have also been developed. The system's design includes the necessary concepts for the implementation and can be realised in a prototype in the next phase.