Refine
Year of publication
Document Type
- Conference Proceeding (93) (remove)
Language
- English (93) (remove)
Keywords
- AAL (1)
- AHI (1)
- Accelerometer (3)
- Accelerometer sensor (1)
- Accelerometers (1)
- Accessibility (1)
- Activity monitoring (1)
- Algorithm (1)
- Ambient assisted living (1)
- Assisted living (1)
Institute
The proposed approach applies current unsupervised clustering approaches in a different dynamic manner. Instead of taking all the data as input and finding clusters among them, the given approach clusters Holter ECG data (long-term electrocardiography data from a holter monitor) on a given interval which enables a dynamic clustering approach (DCA). Therefore advanced clustering techniques based on the well known Dynamic Time Warping algorithm are used. Having clusters e.g. on a daily basis, clusters can be compared by defining cluster shape properties. Doing this gives a measure for variation in unsupervised cluster shapes and may reveal unknown changes in healthiness. Embedding this approach into wearable devices offers advantages over the current techniques. On the one hand users get feedback if their ECG data characteristic changes unforeseeable over time which makes early detection possible. On the other hand cluster properties like biggest or smallest cluster may help a doctor in making diagnoses or observing several patients. Further, on found clusters known processing techniques like stress detection or arrhythmia classification may be applied.
Determination of accelerometer sensor position for respiration rate detection: Initial research
(2022)
Continuous monitoring of a patient's vital signs is essential in many chronic illnesses. The respiratory rate (RR) is one of the vital signs indicating breathing diseases. This article proposes the initial investigation for determining the accelerometric sensor position of a non-invasive and unobtrusive respiratory rate monitoring system. This research aims to determine the sensor position in relation to the patient, which can provide the most accurate values of the mentioned physiological parameter. In order to achieve the result, the particular system setup, including a mechanical sensor holder construction was used. The breathing signals from 5 participants were analyzed corresponding to the relaxed state. The main criterion for selecting a suitable sensor position was each patient's average acceleration amplitude excursion, which corresponds to the respiratory signal. As a result, we provided one more defined important parameter for the considered system, which was not determined before.
Development of an expert system to overpass citizens technological barriers on smart home and living
(2023)
Adopting new technologies can be overwhelming, even for people with experience in the field. For the general public, learning about new implementations, releases, brands, and enhancements can cause them to lose interest. There is a clear need to create point sources and platforms that provide helpful information about the novel and smart technologies, assisting users, technicians, and providers with products and technologies. The purpose of these platforms is twofold, as they can gather and share information on interests common to manufacturers and vendors. This paper presents the ”Finde-Dein-SmartHome” tool. Developed in association with the Smart Home & Living competence center [5] to help users learn about, understand, and purchase available technologies that meet their home automation needs. This tool aims to lower the usability barrier and guide potential customers to clear their doubts about privacy and pricing. Communities can use the information provided by this tool to identify market trends that could eventually lower costs for providers and incentivize access to innovative home technologies and devices supporting long-term care.
Health monitoring in a home environment can have broader use since it may provide continuous control of health parameters with relatively minor intrusiveness into regular life. This work aims to verify if it is possible to replace the typical in some sleep medicine areas subjective questioning by an objective measurement using electronic devices. For this purpose, a study was conducted with ten subjects, in which objective and subjective measurement of relevant sleep parameters took place. The results of both measurement methods were evaluated and analyzed. The results showed that while for some measures, such as Total Time in Bed, there is a high agreement between objective and subjective measurements, for others, such as sleep quality, there are significant differences. For this reason, currently, a combination of both measurement methods may be beneficial and provide the most detailed results, while a partial replacement can already reduce the number of questions at the subjective measurement by measurement through electronic devices.
The last decades have shown that the volume of tourism, in general, is constantly increasing (with some justified exceptions). To offer a possibility of travel for all groups of people, it is necessary to pay attention to accessibility. One of the possibilities for increasing accessibility is digital technologies, which could assist in planning and the implementation and completion of trips. To make a selection of technologies, first, a study of barriers was conducted, which was then analyzed, and finally, some technologies were made available in a test setup. A focus on two technologies was made: 360°-Tours and mobile app with the travel information. The two technologies were implemented and presented to the test subjects.
The evaluation results showed that both technologies could increase accessibility if some essential aspects (such as usability, completeness, relevance, etc.) are considered during the implementation.
Fatigue and drowsiness are responsible for a significant percentage of road traffic accidents. There are several approaches to monitor the driver’s drowsiness, ranging from the driver’s steering behavior to analysis of the driver, e.g. eye tracking, blinking, yawning or electrocardiogram (ECG). This paper describes the development of a low-cost ECG sensor to derive heart rate variability (HRV) data for the drowsiness detection. The work includes the hardware and the software design. The hardware has been implemented on a printed circuit board (PCB) designed so that the board can be used as an extension shield for an Arduino. The PCB contains a double, inverted ECG channel including low-pass filtering and provides two analog outputs to the Arduino, that combined them and performs the analog-to-digital conversion. The digital ECG signal is transferred to an NVidia embedded PC where the processing takes place, including QRS-complex, heart rate and HRV detection as well as visualization features. The compact resulting sensor provides good results in the extraction of the main ECG parameters. The sensor is being used in a larger frame, where facial-recognition-based drowsiness detection is combined with ECG-based detection to improve the recognition rate under unfavorable light or occlusion conditions.
This document presents a new complete standalone system for a recognition of sleep apnea using signals from the pressure sensors placed under the mattress. The developed hardware part of the system is tuned to filter and to amplify the signal. Its software part performs more accurate signal filtering and identification of apnea events. The overall achieved accuracy of the recognition of apnea occurrence is 91%, with the average measured recognition delay of about 15 seconds, which confirms the suitability of the proposed method for future employment. The main aim of the presented approach is the support of the healthcare system with the cost-efficient tool for recognition of sleep apnea in the home environment.
The goal of this paper pretends to show how a bed system with an embedded system with sensor is able to analyze a person’s movement, breathing and recognizing the positions that the subject is lying on the bed during the night without any additional physical contact. The measurements are performed with sensors placed between the mattress and the frame. An Intel Edison board was used as an endpoint that served as a communication node from the mesh network to external service. Two nodes and Intel Edison are attached to the bottom of the bed frame and they are connected to the sensors.
This paper presents a generic method to enhance performance and incorporate temporal information for cardiorespiratory-based sleep stage classification with a limited feature set and limited data. The classification algorithm relies on random forests and a feature set extracted from long-time home monitoring for sleep analysis. Employing temporal feature stacking, the system could be significantly improved in terms of Cohen’s κ and accuracy. The detection performance could be improved for three classes of sleep stages (Wake, REM, Non-REM sleep), four classes (Wake, Non-REM-Light sleep, Non-REM Deep sleep, REM sleep), and five classes (Wake, N1, N2, N3/4, REM sleep) from a κ of 0.44 to 0.58, 0.33 to 0.51, and 0.28 to 0.44 respectively by stacking features before and after the epoch to be classified. Further analysis was done for the optimal length and combination method for this stacking approach. Overall, three methods and a variable duration between 30 s and 30 min have been analyzed. Overnight recordings of 36 healthy subjects from the Interdisciplinary Center for Sleep Medicine at Charité-Universitätsmedizin Berlin and Leave-One-Out-Cross-Validation on a patient-level have been used to validate the method.