Refine
Year of publication
Document Type
- Conference Proceeding (43)
- Article (7)
- Master's Thesis (5)
- Report (4)
- Bachelor Thesis (1)
- Doctoral Thesis (1)
- Other Publications (1)
- Working Paper (1)
Language
- English (63) (remove)
Keywords
Institute
- Fakultät Informatik (63) (remove)
The evaluation of the effectiveness of different machine learning algorithms on a publicly available database of signals derived from wearable devices is presented with the goal of optimizing human activity recognition and classification. Among the wide number of body signals we choose a couple of signals, namely photoplethysmographic (optically detected subcutaneous blood volume) and tri-axis acceleration signals that are easy to be simultaneously acquired using commercial widespread devices (e.g. smartwatches) as well as custom wearable wireless devices designed for sport, healthcare, or clinical purposes. To this end, two widely used algorithms (decision tree and k-nearest neighbor) were tested, and their performance were compared to two new recent algorithms (particle Bernstein and a Monte Carlo-based regression) both in terms of accuracy and processing time. A data preprocessing phase was also considered to improve the performance of the machine learning procedures, in order to reduce the problem size and a detailed analysis of the compression strategy and results is also presented.
The ballistocardiography is a technique that measures the heart rate from the mechanical vibrations of the body due to the heart movement. In this work a novel noninvasive device placed under the mattress of a bed estimates the heart rate using the ballistocardiography. Different algorithms for heart rate estimation have been developed.
Globalization has increased the number of road trips and vehicles. The result has been an intensification of traffic accidents, which are becoming one of the most important causes of death worldwide. Traffic accidents are often due to human error, the probability of which increases when the cognitive ability of the driver decreases. Cognitive capacity is closely related to the driver’s mental state, as well as other external factors such as the CO2 concentration inside the vehicle. The objective of this work is to analyze how these elements affect driving. We have conducted an experiment with 50 drivers who have driven for 25 min using a driving simulator. These drivers completed a survey at the start and end of the experiment to obtain information about their mental state. In addition, during the test, their stress level was monitored using biometric sensors and the state of the environment (temperature, humidity and CO2 level) was recorded. The results of the experiment show that the initial level of stress and tiredness of the driver can have a strong impact on stress, driving behavior and fatigue produced by the driving test. Other elements such as sadness and the conditions of the interior of the vehicle also cause impaired driving and affect compliance with traffic regulations.
The IETF, concerned with the evolution of the Internet architecture, nowadays also looks into industrial automation processes. The contributions of a variety of IETF activities, initiated during the last ten years, enable now the replacement of proprietary standards by an open standardized protocol stack. This stack, denoted in the following as 6TiSCH-stack, is tailored for industrial internet of things (IIoTs). The suitability of 6TiSCH-stack for Industry 4.0 is yet to explore. In this paper, we identify four challenges that, in our opinion, may delay or hinder its adoption. As a prime example of that, we focus on the initial 6TiSCHnetwork
formation, highlighting the shortcomings of the default procedure and introducing our current work for a fast and reliable formation of dense network.
The Industrial Internet of Things (IIoT) will leverage on wireless network technologies to integrate in a seamless manner Cyber-Physical Systems into existing information systems. In this context, the 6TiSCH architecture, proposed by IETF, represents the current leading standardization effort to enable timed and reliable data communication within IPv6 networks for industrial applications. In wireless networks, Link Quality Estimation (LQE) is a crucial task to select the best routes for data forwarding, regardless of unpredictable time varying conditions. Although, many solutions for LQE have been proposed in literature, the majority of them are not designed specifically for 6TiSCH networks. In this paper, we analyze the performance of existing LQE strategies on 6TiSCH networks.
First, we run a set of simulations to measure the performance of one existing LQE strategy in 6TiSCH. Our simulations show that such strategy can result in measurements with low accuracy due to the 6TiSCH default timeslot allocation strategy. Consequently, we propose an extension of the 6TiSCH Minimal Configuration that allocates specific timeslots for the transmission of probing messages to mitigate the problem. The proposed methodology is demonstrated to effectively reduce the LQE error.
The influence of sleep on human life, including physiological, psychological, and mental aspects, is remarkable. Therefore, it is essential to apply appropriate therapy in the case of sleep disorders. For this, however, the irregularities must first be recognised, preferably conveniently for the person concerned. This dissertation, structured as a composition of research articles, presents the development of mathematically based algorithmic principles for a sleep analysis system. The particular focus is on the classification of sleep stages with a minimal set of physiological parameters. In addition, the aspects of using the sleep analysis system as part of the more complex healthcare systems are explored. Design of hardware for non-obtrusive measurement of relevant physiological parameters and the use of such systems to detect other sleep disorders, such as sleep apnoea, are also referred to. Multinomial logistic regression was selected as the basis for development resulting from the investigations carried out. By following a methodical procedure, the number of physiological parameters necessary for the classification of sleep stages was successively reduced to two: Respiratory and Movement signals. These signals might be measured in a contactless way. A prototype implementation of the developed algorithms was performed to validate the proposed method, and the evaluation of 19324 sleep epochs was carried out. The results, with the achieved accuracy of 73% in the classification of Wake/NREM/REM stages and Cohen's kappa of 0.44, outperform the state of the art and demonstrate the appropriateness of the selected approach. In the future, this method could enable convenient, cost-effective, and accurate sleep analysis, leading to the detection of sleep disorders at an early stage so that therapy can be initiated as soon as possible, thus improving the general population's health status and quality of life.
Sleep quality and in general, behavior in bed can be detected using a sleep state analysis. These results can help a subject to regulate sleep and recognize different sleeping disorders. In this work, a sensor grid for pressure and movement detection supporting sleep phase analysis is proposed. In comparison to the leading standard measuring system, which is Polysomnography (PSG), the system proposed in this project is a non-invasive sleep monitoring device. For continuous analysis or home use, the PSG or wearable Actigraphy devices tends to be uncomfortable. Besides this fact, they are also very expensive. The system represented in this work classifies respiration and body movement with only one type of sensor and also in a non-invasive way. The sensor used is a pressure sensor. This sensor is low cost and can be used for commercial proposes. The system was tested by carrying out an experiment that recorded the sleep process of a subject. These recordings showed the potential for classification of breathing rate and body movements. Although previous researches show the use of pressure sensors in recognizing posture and breathing, they have been mostly used by positioning the sensors between the mattress and bedsheet. This project however, shows an innovative way to position the sensors under the mattress.
This document presents a new complete standalone system for a recognition of sleep apnea using signals from the pressure sensors placed under the mattress. The developed hardware part of the system is tuned to filter and to amplify the signal. Its software part performs more accurate signal filtering and identification of apnea events. The overall achieved accuracy of the recognition of apnea occurrence is 91%, with the average measured recognition delay of about 15 seconds, which confirms the suitability of the proposed method for future employment. The main aim of the presented approach is the support of the healthcare system with the cost-efficient tool for recognition of sleep apnea in the home environment.
Objective: This paper presents an algorithm for non-invasive sleep stage identification using respiratory, heart rate and movement signals. The algorithm is part of a system suitable for long-term monitoring in a home environment, which should support experts analysing sleep. Approach: As there is a strong correlation between bio-vital signals and sleep stages, multinomial logistic regression was chosen for categorical distribution of sleep stages. Several derived parameters of three signals (respiratory, heart rate and movement) are input for the proposed method. Sleep recordings of five subjects were used for the training of a machine learning model and 30 overnight recordings collected from 30 individuals with about 27 000 epochs of 30 s intervals each were evaluated. Main results: The achieved rate of accuracy is 72% for Wake, NREM, REM (with Cohen's kappa value 0.67) and 58% for Wake, Light (N1 and N2), Deep (N3) and REM stages (Cohen's kappa is 0.50). Our approach has confirmed the potential of this method and disclosed several ways for its improvement. Significance: The results indicate that respiratory, heart rate and movement signals can be used for sleep studies with a reasonable level of accuracy. These inputs can be obtained in a non-invasive way applying it in a home environment. The proposed system introduces a convenient approach for a long-term monitoring system which could support sleep laboratories. The algorithm which was developed allows for an easy adjustment of input parameters that depend on available signals and for this reason could also be used with various hardware systems.
The recovery of our body and brain from fatigue directly depends on the quality of sleep, which can be determined from the results of a sleep study. The classification of sleep stages is the first step of this study and includes the measurement of vital data and their further processing. The non-invasive sleep analysis system is based on a hardware sensor network of 24 pressure sensors providing sleep phase detection. The pressure sensors are connected to an energy-efficient microcontroller via a system-wide bus. A significant difference between this system and other approaches is the innovative way in which the sensors are placed under the mattress. This feature facilitates the continuous use of the system without any noticeable influence on the sleeping person. The system was tested by conducting experiments that recorded the sleep of various healthy young people. Results indicate the potential to capture respiratory rate and body movement.
The main aim of presented in this manuscript research is to compare the results of objective and subjective measurement of sleep quality for older adults (65+) in the home environment. A total amount of 73 nights was evaluated in this study. Placing under the mattress device was used to obtain objective measurement data, and a common question on perceived sleep quality was asked to collect the subjective sleep quality level. The achieved results confirm the correlation between objective and subjective measurement of sleep quality with the average standard deviation equal to 2 of 10 possible quality points.
Sleep study can be used for detection of sleep quality and in general bed behaviors. These results can helpful for regulating sleep and recognizing different sleeping disorders of human. In comparison to the leading standard measuring system, which is Polysomnography (PSG), the system proposed in this work is a non-invasive sleep monitoring device. For continuous analysis or home use, the PSG or wearable Actigraphy devices tends to be uncomfortable. Besides, these methods not only decrease practicality due to the process of having to put them on, but they are also very expensive. The system proposed in this paper classifies respiration and body movement with only one type of sensor and also in a noninvasive way. The sensor used is a pressure sensor. This sensor is low cost and can be used for commercial proposes. The system was tested by carrying out an experiment that recorded the sleep process of a subject. These recordings showed excellent results in the classification of breathing rate and body movements.
Good sleep is crucial for a healthy life of every person. Unfortunately, its quality often decreases with aging. A common approach to measuring the sleep characteristics is based on interviews with the subjects or letting them fill in a daily questionnaire and afterward evaluating the obtained data. However, this method has time and personal costs for the interviewer and evaluator of responses. Therefore, it would be important to execute the collection and evaluation of sleep characteristics automatically. To do that, it is necessary to investigate the level of agreement between measurements performed in a traditional way using questionnaires and measurements obtained using electronic monitoring devices. The study presented in this manuscript performs this investigation, comparing such sleep characteristics as "time going to bed", "total time in bed", "total sleep time" and "sleep efficiency". A total number of 106 night records of elderly persons (aged 65+) were analyzed. The results achieved so far reveal the fact that the degree of agreement between the two measurement methods varies substantially for different characteristics, from 31 minutes of mean difference for "time going to bed" to 77 minutes for "total sleep time". For this reason, a direct exchange of objective and subjective measuring methods is currently not possible.
This document presents an algorithm for a non-obtrusive recognition of Sleep/Wake states using signals derived from ECG, respiration, and body movement captured while lying in a bed. As a core mathematical base of system data analytics, multinomial logistic regression techniques were chosen. Derived parameters of the three signals are used as the input for the proposed method. The overall achieved accuracy rate is 84% for Wake/Sleep stages, with Cohen’s kappa value 0.46. The presented algorithm should support experts in analyzing sleep quality in more detail. The results confirm the potential of this method and disclose several ways for its improvement.
This paper presents a bed system able to analyze a person’s movement, breathing and recognize the positions that the subject is lying on the bed during the night without any additional physical contact. The measurements are performed with sensors placed between the mattress and the bed-frame. An Intel Edison board was used as an endpoint that served as a communication node from the mesh network to external service. Two nodes and Intel Edison are attached to the bottom of the bed frame and they are connected to the sensors. First test results have indicated the potential of the proposed approach for the recognition of sleep positions with 83% of correct recognized positions.
The process of restoring our body and brain from fatigue is directly depend-ing on the quality of sleep. It can be determined from the report of the sleep study results. Classification of sleep stages is the first step of this study and this includes the measurement of biovital data and its further processing.
In this work, the sleep analysis system is based on a hardware sensor net, namely a grid of 24 pressure sensors, supporting sleep phase recognition. In comparison to the leading standard, which is polysomnography, the proposed approach is a non-invasive system. It recognises respiration and body move-ment with only one type of low-cost pressure sensors forming a mesh archi-tecture. The nodes implement as a series of pressure sensors connected to a low-power and performant microcontroller. All nodes are connected via a system wide bus with address arbitration. The embedded processor is the mesh network endpoint that enables network configuration, storing and pre-processing of the data, external data access and visualization.
The system was tested by executing experiments recording the sleep of different healthy young subjects. The results obtained have indicated the po-tential to detect breathing rate and body movement. A major difference of this system in comparison to other approaches is the innovative way to place the sensors under the mattress. This characteristic facilitates the continuous using of the system without any influence on the common sleep process.
Normal breathing during sleep is essential for people’s health and well-being. Therefore, it is crucial to diagnose apnoea events at an early stage and apply appropriate therapy. Detection of sleep apnoea is a central goal of the system design described in this article. To develop a correctly functioning system, it is first necessary to define the requirements outlined in this manuscript clearly. Furthermore, the selection of appropriate technology for the measurement of respiration is of great importance. Therefore, after performing initial literature research, we have analysed in detail three different methods and made a selection of a proper one according to determined requirements. After considering all the advantages and disadvantages of the three approaches, we decided to use the impedance measurement-based one. As a next step, an initial conceptual design of the algorithm for detecting apnoea events was created. As a result, we developed an activity diagram on which the main system components and data flows are visually represented.
Polysomnography is a gold standard for a sleep study, and it provides very accurate results, but its cost (both personnel and material) are quite high. Therefore, the development of a low-cost system for overnight breathing and heartbeat monitoring, which provides more comfort while recording the data, is a well-motivated challenge. The system proposed in this manuscript is based on the usage of resistive pressure sensors installed under the mattress. These sensors can measure slight pressure changes provoked during breathing and heartbeat. The captured signal requires advanced processing, like applying filters and amplifiers before the analog signal is ready for the next step. Then, the output signal is digitalized and further processed by an algorithm that performs a custom filtering before it can recognize breathing and heart rate in real-time. The result can be directly visualized. Furthermore, a CSV file is created containing the raw data, timestamps, and unique IDs to facilitate further processing. The achieved results are promising, and the average deviation from a reference device is about 4bpm.
Fatigue and drowsiness are responsible for a significant percentage of road traffic accidents. There are several approaches to monitor the driver’s drowsiness, ranging from the driver’s steering behavior to analysis of the driver, e.g. eye tracking, blinking, yawning or electrocardiogram (ECG). This paper describes the development of a low-cost ECG sensor to derive heart rate variability (HRV) data for the drowsiness detection. The work includes the hardware and the software design. The hardware has been implemented on a printed circuit board (PCB) designed so that the board can be used as an extension shield for an Arduino. The PCB contains a double, inverted ECG channel including low-pass filtering and provides two analog outputs to the Arduino, that combined them and performs the analog-to-digital conversion. The digital ECG signal is transferred to an NVidia embedded PC where the processing takes place, including QRS-complex, heart rate and HRV detection as well as visualization features. The compact resulting sensor provides good results in the extraction of the main ECG parameters. The sensor is being used in a larger frame, where facial-recognition-based drowsiness detection is combined with ECG-based detection to improve the recognition rate under unfavorable light or occlusion conditions.
This thesis deals with background, theory, design, layout and experimental test results of an analogue CMOS VLSI current-mode analog-to-digital converter. This system supports a project, whose goal it is to build a biologically relevant model of synaptic plasticity, named the Artificial Synapse. A critical part of the design, which is based on analogue CMOS VLSI circuits, is the ability to activate a discrete number of channels by sampling an analogue signal. Since currents are the signal of interest and transistors are biased in weak inversion (subthreshold regime), the system requires a current mode A/D circuit that it can operate at ultra-low power and current levels. To meet this need, two new innovative A/D converter approaches are proposed to replace the system’s previous A/D converter design which suffered from a non-linear resolution, uncoded output code and heavy bit oscillations. The initial technical requirements and key criteria for the new converter comprise a resolution of one nano ampere, an input current range between 0 – 100nA, conversion frequencies of up to 5kHz, and a power supply voltage of less than 1.5V. Temperature range, space occupation and power dissipation aspects were not specified due to the early stage of the related Artificial Synapse project. The novel converters both produce seven bit thermometer codes, their functional principle can be best described as current mode flash analog-to-digital converters (ADCs). Due to the fact that the input signal is in the area of a subthreshold current, it is selfevident that the A/D converter design should operate at a subthreshold realm. To support low power operation, clocks or high currents could not be used and were excluded from the design from the very start. To encode the thermometer code into standard binary code, a seven-to-three encoder was designed and integrated on the chip. In October 2003, the design was submitted for production to the MOSIS circuit fabrication service. The AMI Semiconductor 1.5 micron ABN CMOS process was chosen to manufacture the chip. When it was returned in January 2004, simulation results showed that both new A/D converter approaches accomplished excellent results which were expected from SPICE simulation results. With the new chip installed, it became possible to resolve input currents as small as one nano ampere and achieve conversion frequencies of up to 5kHz. The circuits also both meet the requirements which were set at the beginning of the project to operate at a power supply voltage of less than 1.5V, processing input currents in the range between 0 – 100nA. A prototype printed circuit board (PCB) was developed, produced and employed for experiments with the chip. The major application of this test-bed is the ability to generate and measure extremely low currents with high precision. This enables the monitoring of the very small currents that are processed by the chip.
The exposure to the light has a great influence on human beings in their everyday life. Various lighting sources produce light that reaches the human eye and influences a rhythmic release of melatonin hormone, that is a sleep promoting factor.
Since the development of new technologies provides more control over illuminance, this work uses an IoT based lighting system to set up dim and bright scenarios. A small study has been performed on the influence of illuminance on sleep latency. The system consists of different light bulbs, sensors and a central bridge which are interconnected like a mesh network. Also, a mobile app has been developed, that allows to adjust the lighting in various rooms. With the help of a ferro-electret sensor, like applied in sleep monitoring systems, a subject’s sleep was monitored. The sensor is placed below the mattress and it collects data, which is stored and processed in a cloud or in other alternative locations.
The research was conducted on healthy young subjects after being previously exposed to the preconfigured illuminance for at least three hours before bedtime. The results indicate correlation between sleep onset latency and exposure to different illuminance before bedtime. In a dimmed environment, the subject fell asleep in average 28% faster compared to the brighter environment.
Dynamic Real-Time Range Queries (DRRQ) are a common means to handle mobile clients in high-density areas where both, clients requested by the query and the inquirers, are mobile. In contrast to the very well-known continuous range queries, only a few approaches, such as Adaptive Quad Streaming (AQS), address the mandatory scalability and real-time requirements of these so-called ad-hoc mobility challenges. In this paper we present the highly decentralized solution Adaptive Quad Streaming Flexible (AQSflex) as an extension of the already existing more theoretical AQS approach. Beside a highly distributed cell structure without data structures and a lightweight streaming communication, we use a multi-cell-assignment on limited pool resources instead of an idealistic unlimited cell-per-server assignment. The described experimental results show the potential of our local capacity balancing scheme for cell handover in a strongly decentralized setting. Leafs of a cell hierarchy define a kind of self-optimizing fuzzy edge for the processing resources in high-density systems without any centralized controlling or cloud component.
This thesis emphasizes problems that reports generated by vulnerability scanners impose on the process of vulnerability management, which are a. an overwhelming amount of data and b. an insufficient prioritization of the scan results.
To assist the process of developing means to counteract those problems and to allow for quantitative evaluation of their solutions, two metrics are proposed for their effectiveness and efficiency. These metrics imply a focus on higher severity vulnerabilities and can be applied to any simplification process of vulnerability scan results, given it relies on a severity score and time of remediation estimation for each vulnerability.
A priority score is introduced which aims to improve the widely used Common Vulnerability Scoring System (CVSS) base score of each vulnerability dependent on a vulnerability’s ease of exploit, estimated probability of exploitation and probability of its existence.
Patterns within the reports generated by the Open Vulnerability Assessment System (OpenVAS) vulnerability scanner between vulnerabilities are discovered which identify criteria by which they can be categorized from a remediation actor standpoint. These categories lay the groundwork of a final simplified report and consist of updates that need to be installed on a host, severe vulnerabilities, vulnerabilities that occur on multiple hosts and vulnerabilities that will take a lot of time for remediation. The highest potential time savings are found to exist within frequently occurring vulnerabilities, minor- and major suggested updates.
Processing of the results provided by the vulnerability scanner and creation of the report is realized in the form of a python script. The resulting reports are short, straight to the point and provide a top down remediation process which should theoretically allow to minimize the institutions attack surface as fast as possible. Evaluation of the practicality must follow as the reports are yet to be introduced into the Information Security Management Lifecycle.
Background:
One of the most promising health care development areas is introducing telemedicine services and creating solutions based on blockchain technology. The study of systems combining both these domains indicates the ongoing expansion of digital technologies in this market segment.
Objective:
This paper aims to review the feasibility of blockchain technology for telemedicine.
Methods:
The authors identified relevant studies via systematic searches of databases including PubMed, Scopus, Web of Science, IEEE Xplore, and Google Scholar. The suitability of each for inclusion in this review was assessed independently. Owing to the lack of publications, available blockchain-based tokens were discovered via conventional web search engines (Google, Yahoo, and Yandex).
Results:
Of the 40 discovered projects, only 18 met the selection criteria. The 5 most prevalent features of the available solutions (N=18) were medical data access (14/18, 78%), medical service processing (14/18, 78%), diagnostic support (10/18, 56%), payment transactions (10/18, 56%), and fundraising for telemedical instrument development (5/18, 28%).
Conclusions:
These different features (eg, medical data access, medical service processing, epidemiology reporting, diagnostic support, and treatment support) allow us to discuss the possibilities for integration of blockchain technology into telemedicine and health care on different levels. In this area, a wide range of tasks can be identified that could be accomplished based on digital technologies using blockchains.
Interpretability and uncertainty modeling are important key factors for medical applications. Moreover, data in medicine are often available as a combination of unstructured data like images and structured predictors like patient’s metadata. While deep learning models are state-of-the-art for image classification, the models are often referred to as ’black-box’, caused by the lack of interpretability. Moreover, DL models are often yielding point predictions and are too confident about the parameter estimation and outcome predictions.
On the other side with statistical regression models, it is possible to obtain interpretable predictor effects and capture parameter and model uncertainty based on the Bayesian approach. In this thesis, a publicly available melanoma dataset, consisting of skin lesions and patient’s age, is used to predict the melanoma types by using a semi-structured model, while interpretable components and model uncertainty is quantified. For Bayesian models, transformation model-based variational inference (TM-VI) method is used to determine the posterior distribution of the parameter. Several model constellations consisting of patient’s age and/or skin lesion were implemented and evaluated. Predictive performance was shown to be best by using a combined model of image and patient’s age, while providing the interpretable posterior distribution of the regression coefficient is possible. In addition, integrating uncertainty in image and tabular parts results in larger variability of the outputs corresponding to high uncertainty of the single model components.
The target of this thesis is the introduction of a client management system (CMS) at Haaland Internet Productions (HiP), a web design and hosting company in Burbank, California, USA. The company needs a system to track orders and improve workflow. HiP needs a system which not only tracks orders, but also stores all client information in a database. This client information can be used for a variety of marketing and contact reasons. It is an important and integral part of HiP's client relationship management (CRM). The lack of a cohesive CMS at HiP caused many fundamental business problems, such as lost orders, missed billing statements, and over/under billing. The research done during the investigation and analysis of the company and their needs should lead to a global system which totally fulfils the needs of HiP. This global system could be in the form of an off-the-shelf product with some customizations, or a completely new, in-house system. Either solution will have respective pros and cons; the goal is to reach a decision that best fits HiP's needs and situation. The following is a concise version of the project. Particular emphasis is placed upon the single steps which made up the decision process, as well as the practiced techniques, methods, and their applications.
This work treats with the segmentation of 2D environment Laser data, captured by an Autonomous Mobile Indoor Robot. It is part of the data processing, which is necessary to navigate a mobile robot error free in its environment. The whole process can generally be described by data capturing, data processing and navigation. In this project the data processing deals with data, captured by a Laser-Sensor, which provides two dimensional data by a series of distance measurements i.e. point-measurements of the environment. These point series have to be filtered and processed into a more convenient representation to provide a virtual environment map, which can be used of the robot for an error free navigation. This project provides different solutions of the same problem: the conversion from distance points to model segments which should represent the real world environment as close as possible. The advantages and disadvantages of each of the different Segmentation-Algorithms will be shown as well as a comparison taking into account the Computational Time and the Robustness of the results.
Preliminary results of homomorphic deconvolution application to surface EMG signals during walking
(2021)
Homomorphic deconvolution is applied to sEMG signals recorded during walking. Gastrocnemius lateralis and tibialis anterior signals were acquired according to SENIAM recommendation. MUAP parameters like amplitude and scale were estimated, whilst the MUAP shape parameter was fixed. This features a useful time-frequency representation of sEMG signal. Estimation of scale MUAP parameter was verified extracting the mean frequency of filtered EMG signal, extracted from the scale parameter estimated with two different MUAP shape values.
We identify 74 generic, reusable technical requirements based on the GDPR that can be applied to software products which process personal data. The requirements can be traced to corresponding articles and recitals of the GDPR and fulfill the key principles of lawfulness and transparency. Therefore, we present an approach to requirements engineering with regard to developing legally compliant software that satisfies the principles of privacy by design, privacy by default as well as security by design.
The overall goal of this work is to detect and analyze a person's movement, breathing and heart rate during sleep in a common bed overnight without any additional physical contact. The measurement is performed with the help of
sensors placed between the mattress and the frame. A two-stage pattern classification algorithm based has been implemented that applies statistics analysis to recognize the position of patients. The system is implemented in a sensors-network, hosting several nodes and communication end-points to support quick and efficient classification. The overall tests show convincing results for the position recognition and a reasonable overlap in matching.
The cornerstone of cognitive systems is environment awareness which enables agile and adaptive use of channel resources. Whitespace prediction based on learning the statistics of the wireless traffic has proven to be a powerful tool to achieve such awareness. In this paper, we propose a novel Hidden Markov Model (HMM) based spectrum learning and prediction approach which accurately estimates the exact length of the whitespace in WiFi channels within the shared industrial scientific medical ISM) bands. We show that extending the number of hidden states and formulating the prediction problem as a maximum likelihood (ML) classification leads to a substantial increase in the prediction horizon compared to classical approaches that predict the immediate (short-term) future. We verify the proposed algorithm through simulations which utilize a model for WiFi traffic based on extensive measurement campaigns.
A significant proportion of road traffic accidents are due to inattentiveness or fatigue at the wheel. Approaches to monitoring the driver's condition range from eye tracking and driving behavior analysis to yawn and blink detection and ECG measurement. This work describes the development of a mobile system for the measurement and processing of ECG data. The aim of the signal processing is to quantify the driver’s fatigue with the heartrate variability (HRV). The work includes the hardware and software design of the sensor. First, the development of low-noise electronics including AD conversion is described. Then the software signal processing with QRS complex detection and plotting front end is explained. The resulting sensor is compact, low-cost and provides a good signal for HRV extraction.
The number of home office workers sitting for many hours is increasing. The sensor chair is tracking users’ sitting behavior which the help of pressure sensors and tries to avoid wrong postures which may cause diseases. The system provides live monitoring of the pressure distribution via web interface, as well as sitting posture prediction in real time. Posture analysis is realized through machine learning algorithm using a decision tree classifier that is compared to a random forest. Data acquisition and aggregation for the learning process happens with a mobile app adding users biometrical data and the taken sitting posture as label. The sensor chair is able to differentiate between an arched back, a neutral posture or a laid back position taken on the chair. The classifier achieves an accuracy of 97.4% on our test set and is comparable to the performance of the random forest with 98.9%.
Cardiovascular diseases are directly or indirectly responsible for up to 38.5% of all deaths in Germany and thus represent the most frequent cause of death. At present, heart diseases are mainly discovered by chance during routine visits to the doctor or when acute symptoms occur. However, there is no practical method to proactively detect diseases or abnormalities of the heart in the daily environment and to take preventive measures for the person concerned. Long-term ECG devices, as currently used by physicians, are simply too expensive, impractical, and not widely available for everyday use. This work aims to develop an ECG device suitable for everyday use that can be worn directly on the body. For this purpose, an already existing hardware platform will be analyzed, and the corresponding potential for improvement will be identified. A precise picture of the existing data quality is obtained by metrological examination, and corresponding requirements are defined. Based on these identified optimization potentials, a new ECG device is developed. The revised ECG device is characterized by a high integration density and combines all components directly on one board except the battery and the ECG electrodes. The compact design allows the device to be attached directly to the chest. An integrated microcontroller allows digital signal processing without the need for an additional computer. Central features of the evaluation are a peak detection for detecting R-peaks and a calculation of the current heart rate based on the RR interval. To ensure the validity of the detected R-peaks, a model of the anatomical conditions is used. Thus, unrealistic RR-intervals can be excluded. The wireless interface allows continuous transmission of the calculated heart rate. Following the development of hardware and software, the results are verified, and appropriate conclusions about the data quality are drawn. As a result, a very compact and wearable ECG device with different wireless technologies, data storage, and evaluation of RR intervals was developed. Some tests yelled runtimes up to 24 hours with wireless Lan activated and streaming.
In previous studies, we used a method for detecting stress that was based exclusively on heart rate and ECG for differentiation between such situations as mental stress, physical activity, relaxation, and rest. As a response of the heart to these situations, we observed different behavior in the Root Mean Square of the Successive differences heartbeats (RMSSD). This study aims to analyze Virtual Reality via a virtual reality headset as an effective stressor for future works. The value of the Root Mean Square of the Successive Differences is an important marker for the parasympathetic effector on the heart and can provide information about stress. For these measurements, the RR interval was collected using a breast belt. In these studies, we can observe the Root Mean Square of the successive differences heartbeats. Additional sensors for the analysis were not used. We conducted experiments with ten subjects that had to drive a simulator for 25 minutes using monitors and 25 minutes using virtual reality headset. Before starting and after finishing each simulation, the subjects had to complete a survey in which they had to describe their mental state. The experiment results show that driving using virtual reality headset has some influence on the heart rate and RMSSD, but it does not significantly increase the stress of driving.
The investigation of stress requires to distinguish between stress caused by physical activity and stress that is caused by psychosocial factors. The behaviour of the heart in response to stress and physical activity is very similar in case the set of monitored parameters is reduced to one. Currently, the differentiation remains difficult and methods which only use the heart rate are not able to differentiate between stress and physical activity, without using additional sensor data input. The approach focusses on methods which generate signals providing characteristics that are useful for detecting stress, physical activity, no activity and relaxation.
Methods based exclusively on heart rate hardly allow to differentiate between physical activity, stress, relaxation, and rest, that is why an additional sensor like activity/movement sensor added for detection and classification. The response of the heart to physical activity, stress, relaxation, and no activity can be very similar. In this study, we can observe the influence of induced stress and analyze which metrics could be considered for its detection. The changes in the Root Mean Square of the Successive Differences provide us with information about physiological changes. A set of measurements collecting the RR intervals was taken. The intervals are used as a parameter to distinguish four different stages. Parameters like skin conductivity or skin temperature were not used because the main aim is to maintain a minimum number of sensors and devices and thereby to increase the wearability in the future.
Web services are, due to the excellent tool support, simple to provide and use in trivial cases. But their use in non-trivial Web service-based systems like I3M poses new difficulties and problems. I3M is an instant messaging and chat system with distributed and local components collaborating via Web services. One difficulty is to make a series of related Web service invocations in a stateful session. A problem is the performance of collaborating collocated, service-oriented components of a system due to the high Web service invocation overheaed as is shown by measurements. Solutions to both the difficulty and the problem are proposed.
To get a better understanding of Cross Site Scripting vulnerabilities, we investigated 50 randomly selected CVE reports which are related to open source projects. The vulnerable and patched source code was manually reviewed to find out what kind of source code patterns were used. Source code pattern categories were found for sources, concatenations, sinks, html context and fixes. Our resulting categories are compared to categories from CWE. A source code sample which might have led developers to believe that the data was already sanitized is described in detail. For the different html context categories, the necessary Cross Site Scripting prevention mechanisms are described.
We investigated 50 randomly selected buffer overflow vulnerabilities in Firefox. The source code of these vulnerabilities and the corresponding patches were manually reviewed and patterns were identified. Our main contribution are taxonomies of errors, sinks and fixes seen from a developer's point of view. The results are compared to the CWE taxonomy with an emphasis on vulnerability details. Additionally, some ideas are presented on how the taxonomy could be used to improve the software security education.
We present source code patterns that are difficult for modern static code analysis tools. Our study comprises 50 different open source projects in both a vulnerable and a fixed version for XSS vulnerabilities reported with CVE IDs over a period of seven years. We used three commercial and two open source static code analysis tools. Based on the reported vulnerabilities we discovered code patterns that appear to be difficult to classify by static analysis. The results show that code analysis tools are helpful, but still have problems with specific source code patterns. These patterns should be a focus in training for developers.
We compared vulnerable and fixed versions of the source code of 50 different PHP open source projects based on CVE reports for SQL injection vulnerabilities. We scanned the source code with commercial and open source tools for static code analysis. Our results show that five current state-of-the-art tools have issues correctly marking vulnerable and safe code. We identify 25 code patterns that are not detected as a vulnerability by at least one of the tools and 6 code patterns that are mistakenly reported as a vulnerability that cannot be confirmed by manual code inspection. Knowledge of the patterns could help vendors of static code analysis tools, and software developers could be instructed to avoid patterns that confuse automated tools.